|
||||||||||||||||||||||||||||||||||
Extension cartridge W-SC-M
|
Solenoid valve thermal disinfection
|
Angle valve with regulating function COMFORT with filter
|
SSC Bluetooth® module
|
Radiator screw connection
|
Concealed shower LINUS D-SC-M
|
Exposed wash basin tap WALIS E
|
Concealed shower LINUS D-C-T
|
Concealed shower LINUS Basic D-C-V
|
Tap hole rosette PETIT SC
|
Electronic wash basin tap XERIS E
|
Electronic wash basin tap XERIS E
|
Exposed shower tap VITUS VD open/close-T / u
|
Exposed shower tap VITUS VD -C-T / u
|
Electronic kitchen tap GRANDISÂ E
|
Flow regulator low pressure
|
Electronic wash basin tap PURIS E
|
Electronic wash basin tap PURIS E
|
Exposed wash basin tap VITUS VW-C-T
|
Exposed wash basin tap VITUS VW-E-T
|
Angle valve thermostat set
|
Exposed wash basin tap VITUS VW-SC-M
|
Exposed wash basin tap VITUS VW-open/close-T
|
Flow regulator max. 5.0 l/min pressure-independent
|
Concealed wash basin tap LINUS W-E-M
|
Concealed wash basin tap LINUS W-E-V
|
Radiator screw connection
|
Electronic wash basin tap XERIS E
|
Concealed WC flush valves COMPACT II
|
Concealed wash basin tap LINUS W-E-V
|
Concealed wash basin tap LINUS W-E-V
|
Electronic wash basin tap XERIS E
|
Electronic wash basin tap XERIS E-T
|
Electronic wash basin tap XERIS E
|
|
Mixed water
|
Monostable, 12 V
|
Mixed water
|
Cold water/pre-mixed water
|
Mixed water, ThermoProtect thermostat
|
Pre-mixed water
|
HD-K small - high-pressure cold water/pre-mixed water
|
HD-M mid - high-pressure mixed water
|
Mixed water, ThermoProtect thermostat
|
Mixed water, ThermoProtect thermostat
|
HD-M - high-pressure mixed water
|
HD-M - high-pressure mixed water
|
ND-M - low pressure mixed water
|
Mixed water, ThermoProtect thermostat
|
Mixed water, ThermoProtect thermostat
|
Flexible design
|
Mixed water
|
Mixed water, ThermoProtect thermostat
|
Laminar jet
|
Mixed water
|
Cold water/pre-mixed water
|
HD-K mid. - high-pressure cold water/pre-mixed water
|
Cold water/pre-mixed water
|
Cold water/pre-mixed water
|
HD-K large - high-pressure cold water/pre-mixed water
|
HD-M mid - high-pressure mixed water, ThermoProtect thermostat
|
HD-M small - high-pressure mixed water
|
||||||||
Article number
|
||||||||||||||||||||||||||||||||||
Extension when installation of the concealed WBW-SC-M masterbox is too deep.
|
Solenoid valve can be retrofitted to the planned connection in a water path. Function: Hot water is routed to bypass the thermostatic valve. Selection is made by using the on-site connection (central building control system, key switch, etc.).
|
With COMFORT handle. To protect high-quality fittings, e.g. electronically controlled fittings. According to DIN 3227.
|
For the wireless parametrisation of SSC-capable SCHELL fittings or for the optional extension of stagnation flushes. Access via SSC Bluetooth® app (can be downloaded from App Store, Play Store) and mobile Android or iOS devices. Usable as a tool for adjusting the fittings (module can then be removed). Or the module is left on the fitting (excepting VITUS shower fittings, SCHELLTRONIC urinal flush valves, and battery-operated PURIS E and VENUS E) and therefore enables stagnation flushes by weekday and by time of day. The last 64 stagnation flushes are stored and can be accessed via the app. This data can also be sent/exported via email as a CSV file if required. Access to the SSC Bluetooth® module is protected by an access code that can be changed individually.
|
According to DIN 3842 for compact radiators. Straight form, lockable/adjustable.
|
For WBD-SC-M concealed masterbox. Manual actuation with automatic closing.
|
Infrared sensor-controlled. Battery operation. Suitable for networking with the SCHELL SWS water management system. Configurable via SCHELL Single Control SSC. Connection from rear or, with optional mounting frame, from top, bottom or sides.
|
For WBD-E-T concealed masterbox. Triggering via CVD-Touch electronics with automatic closing. Optional battery or mains operation. Suitable for networking with the SCHELL SWS water management system. Configurable via SCHELL Single Control SSC.
|
For WBD-E-V concealed masterbox. Triggering via CVD-Touch electronics with automatic closing. Optional battery or mains operation. Suitable for networking with the SCHELL SWS water management system. Configurable via SCHELL Single Control SSC.
|
For wash basins with tap hole that is too large.
|
Infrared sensor-controlled. Excluding power supply. Suitable for networking with the SCHELL SWS water management system. Configurable via SCHELL Single Control SSC. Intended for power supply via SCHELL water management system SWS or central power supply unit.
|
Infrared sensor-controlled. Excluding power supply. Suitable for networking with the SCHELL SWS water management system. Configurable via SCHELL Single Control SSC. Intended for power supply via SCHELL water management system SWS or central power supply unit.
|
Manual open/closed actuation. Shower connection at bottom.
|
Triggering via CVD-Touch electronics with automatic closing. Battery operation. Shower connection at bottom. Suitable for networking with the SCHELL SWS water management system. Configurable via SCHELL Single Control SSC.
|
Infrared sensor-controlled. Additional single-lever operation. Battery operation. Suitable for networking with the SCHELL SWS water management system. Configurable via SCHELL Single Control SSC. Stagnation flushing in the mixing ratio of the touch-free actuation, independent of the single-lever position.
|
For all PURIS E low-pressure wash basin taps.
|
Infrared sensor-controlled. Battery operation. Suitable for networking with the SCHELL SWS water management system. Configurable via SCHELL Single Control SSC.
|
Infrared sensor-controlled. Battery operation. Suitable for networking with the SCHELL SWS water management system. Configurable via SCHELL Single Control SSC. For open hot water storage tanks.
|
Triggering via CVD-Touch electronics with automatic closing. Battery operation. With integrated SWS BE-F VITUS wireless bus extender for networking with the SWS water management system.
|
Infrared sensor-controlled. Battery operation. With integrated SWS BE-F VITUS wireless bus extender for networking with the SWS water management system.
|
Thermostatic anti-scalding protection fitting incl. flexible connecting set for installation on angle valves with G 3/8 AG outlet. Setting of max. draw-off temperature, concealed under cover cap, only possible with tool.
|
Manual actuation with automatic closing. Easy flow time adjustment.
|
Manual open/closed actuation.
|
For all SCHELL wash basin taps PURIS, VENUS, CELIS, MODUS and PETIT. Not suitable for low pressure taps.
|
For WBW-E-M concealed masterbox. Infrared sensor-controlled. Excluding power supply. Suitable for networking with the SCHELL SWS water management system. Configurable via SCHELL Single Control SSC. Intended for power supply via SCHELL water management system SWS or central power supply unit.
|
For WBW-E-V concealed masterbox. Infrared sensor-controlled. Excluding power supply. Suitable for networking with the SCHELL SWS water management system. Configurable via SCHELL Single Control SSC. Intended for power supply via SCHELL water management system SWS or central power supply unit.
|
According to DIN 3842 for compact radiators. Straight form.
|
Infrared sensor-controlled. Battery operation. Suitable for networking with the SCHELL SWS water management system. Configurable via SCHELL Single Control SSC.
|
Low-noise concealed flush valve. For combination with all SCHELL WC controls/operating panels. Conform to DIN EN 12541. Internal isolating valve.
|
For WBW-E-V concealed masterbox. Infrared sensor-controlled. Mains operation. Suitable for networking with the SCHELL SWS water management system. Configurable via SCHELL Single Control SSC.
|
For WBW-E-V concealed masterbox. Infrared sensor-controlled. Excluding power supply. Suitable for networking with the SCHELL SWS water management system. Configurable via SCHELL Single Control SSC. Intended for power supply via SCHELL water management system SWS or central power supply unit.
|
Infrared sensor-controlled. Mains operation (transformer plug). Suitable for networking with the SCHELL SWS water management system. Configurable via SCHELL Single Control SSC.
|
Infrared sensor-controlled. Mains operation (transformer plug). Suitable for networking with the SCHELL SWS water management system. Configurable via SCHELL Single Control SSC.
|
Infrared sensor-controlled. Mains operation (concealed transformer). Suitable for networking with the SCHELL SWS water management system. Configurable via SCHELL Single Control SSC.
|
|
Delivery data
|
Scope of delivery
Delivery data
|
Scope of delivery
Delivery data
|
Scope of delivery
Delivery data
|
Scope of delivery
Delivery data
|
Scope of delivery
Delivery data
|
Scope of delivery
Delivery data
|
Scope of delivery
Delivery data
|
Scope of delivery
Delivery data
|
Scope of delivery
Delivery data
|
Scope of delivery
Delivery data
|
Scope of delivery
Delivery data
|
Scope of delivery
Delivery data
|
Scope of delivery
Delivery data
|
Scope of delivery
Delivery data
|
Scope of delivery
Delivery data
|
Scope of delivery
Delivery data
|
Scope of delivery
Delivery data
|
Scope of delivery
Delivery data
|
Scope of delivery
Delivery data
|
Scope of deliveryAngle valve thermostat (09 414 06 99)
Delivery data
|
Scope of delivery
Delivery data
|
Scope of delivery
Delivery data
|
Scope of delivery
Delivery data
|
Scope of delivery
Delivery data
|
Scope of delivery
Delivery data
|
Scope of delivery
Delivery data
|
Scope of delivery
Delivery data
|
Scope of delivery
Delivery data
|
Scope of delivery
Delivery data
|
Scope of delivery
Delivery data
|
Scope of delivery
Delivery data
|
Scope of delivery
Delivery data
|
Scope of delivery
Delivery data
|
|
Technical data
|
|
Technical data
|
Technical data
|
Technical data
|
Technical data
|
Technical data
|
Technical data
|
Technical data
|
|
Technical data
|
Technical data
|
Technical data
|
Technical data
|
Technical data
|
Technical data
|
Technical data
|
Technical data
|
Technical data
|
Technical data
|
Technical dataAngle valve thermostat (09 414 06 99)
|
Technical data
|
Technical data
|
Technical data
|
Technical data
|
Technical data
|
Technical data
|
Technical data
|
Technical data
|
Technical data
|
Technical data
|
Technical data
|
Technical data
|
Technical data
|
|
Filter categories
|
||||||||||||||||||||||||||||||||||
Energy supply
|
-
|
Mains operation
|
-
|
-
|
-
|
-
|
Battery mode
|
Battery operation,
Mains operation, via SWS or central power pack |
Battery operation,
Mains operation, via SWS or central power pack |
-
|
via SWS or central power pack
|
via SWS or central power pack
|
-
|
Battery mode,
Battery operation |
Battery mode,
Battery operation |
-
|
Battery mode
|
Battery mode
|
Battery mode
|
Battery mode
|
-
|
-
|
-
|
-
|
via SWS or central power pack
|
via SWS or central power pack
|
-
|
Battery mode
|
-
|
Mains mode
|
via SWS or central power pack
|
Mains mode
|
Mains mode
|
Mains mode
|
Connection
|
-
|
-
|
1/2",
ASAG/ASAG easy |
-
|
-
|
-
|
1/2"
|
-
|
-
|
-
|
3/8"
|
3/8"
|
-
|
-
|
3/8"
|
-
|
3/8"
|
3/8"
|
1/2"
|
-
|
3/8"
|
-
|
-
|
-
|
-
|
-
|
-
|
3/8"
|
-
|
-
|
-
|
3/8"
|
3/8"
|
3/8"
|
Outlet
|
-
|
-
|
3/8",
Compression connection |
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
3/8"
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
Finish
|
-
|
-
|
Chrome
|
-
|
-
|
Chrome
|
Chrome
|
Stainless steel
|
Stainless steel
|
-
|
Chrome
|
Chrome
|
Chrome
|
Chrome
|
Chrome
|
-
|
Chrome
|
Chrome
|
Chrome
|
Chrome
|
Chrome
|
Chrome
|
Chrome
|
-
|
Chrome
|
Chrome
|
-
|
Chrome
|
-
|
Chrome
|
Chrome
|
Chrome
|
Chrome
|
Chrome
|
Noises
|
-
|
-
|
Noise class 1
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
Noise class 1
|
Noise class 1
|
-
|
-
|
Noise class 1
|
-
|
Noise class 1
|
Noise class 1
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
Noise class 1
|
Noise class 1
|
-
|
-
|
Noise class 1
|
Noise class 1
|
Noise class 1
|
Equipment
|
-
|
-
|
Filter
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
Backflow preventer,
Filter, Flow restrictor |
Backflow preventer,
Filter, Flow restrictor |
-
|
-
|
Filter,
Backflow preventer |
-
|
Filter,
Backflow preventer |
Filter,
Flow restrictor |
Backflow preventer
|
Backflow preventer,
Flow restrictor |
Filter,
Backflow preventer |
-
|
-
|
-
|
-
|
-
|
-
|
Backflow preventer,
Filter, Flow restrictor |
-
|
-
|
-
|
Backflow preventer,
Filter, Flow restrictor |
Backflow preventer,
Filter, Flow restrictor |
Backflow preventer,
Filter, Flow restrictor |
System solutions
|
-
|
-
|
-
|
Single Control SSC
|
-
|
-
|
SWS Water Management System,
Single Control SSC |
SWS Water Management System,
Single Control SSC |
SWS Water Management System,
Single Control SSC |
-
|
SWS Water Management System,
Single Control SSC |
SWS Water Management System,
Single Control SSC |
-
|
SWS Water Management System,
Single Control SSC |
SWS Water Management System,
Single Control SSC |
-
|
SWS Water Management System,
Single Control SSC |
SWS Water Management System,
Single Control SSC |
SWS Water Management System,
Single Control SSC |
SWS Water Management System,
Single Control SSC |
-
|
-
|
-
|
-
|
SWS Water Management System,
Single Control SSC |
SWS Water Management System,
Single Control SSC |
-
|
SWS Water Management System,
Single Control SSC |
SWS Water Management System,
Single Control SSC |
SWS Water Management System,
Single Control SSC |
SWS Water Management System,
Single Control SSC |
SWS Water Management System,
Single Control SSC |
SWS Water Management System,
Single Control SSC |
SWS Water Management System,
Single Control SSC |
Function
|
-
|
-
|
-
|
-
|
-
|
Self-closing mechanical
|
Contact-free,
Self-closing electronic |
Self-closing electronic
|
Self-closing electronic
|
-
|
Contact-free,
Self-closing electronic |
Contact-free,
Self-closing electronic |
Open/closed
|
Self-closing electronic
|
Single lever,
Contact-free, Self-closing electronic |
-
|
Contact-free,
Self-closing electronic |
Contact-free,
Self-closing electronic |
Self-closing electronic
|
Contact-free,
Self-closing electronic |
-
|
Self-closing mechanical
|
Open/closed
|
-
|
Contact-free,
Self-closing electronic |
Contact-free,
Self-closing electronic |
-
|
Contact-free,
Self-closing electronic |
Contact-free,
Self-closing electronic, Self-closing mechanical |
Contact-free,
Self-closing electronic |
Contact-free,
Self-closing electronic |
Contact-free,
Self-closing electronic |
Contact-free,
Self-closing electronic |
Contact-free,
Self-closing electronic |
Temperature
|
-
|
-
|
-
|
-
|
-
|
Mixed water
|
Cold water/pre-m. water
|
Thermostat (incl. scald protection),
Mixed water |
Cold water/pre-m. water
|
-
|
Cold water/pre-m. water
|
Mixed water
|
Thermostat (incl. scald protection),
Mixed water |
Thermostat (incl. scald protection),
Mixed water |
Mixed water
|
-
|
Mixed water
|
Mixed water,
Mixed water (low-pressure) |
Thermostat (incl. scald protection)
|
Thermostat (incl. scald protection),
Mixed water |
Thermostat (incl. scald protection)
|
Mixed water
|
Thermostat (incl. scald protection),
Mixed water |
-
|
Mixed water
|
Cold water/pre-m. water
|
-
|
Cold water/pre-m. water
|
Mixed water
|
Cold water/pre-m. water
|
Cold water/pre-m. water
|
Cold water/pre-m. water
|
Thermostat (incl. scald protection),
Mixed water |
Mixed water
|
Hygiene
|
-
|
-
|
-
|
-
|
-
|
-
|
Stagnation flush,
Therm. disinfection |
Stagnation flush,
Therm. disinfection |
Stagnation flush
|
-
|
Stagnation flush
|
Stagnation flush,
Therm. disinfection |
Therm. disinfection
|
Stagnation flush
|
Stagnation flush,
Therm. disinfection |
-
|
Stagnation flush
|
Stagnation flush
|
Stagnation flush
|
Stagnation flush,
Therm. disinfection |
Therm. disinfection
|
Therm. disinfection
|
-
|
-
|
Stagnation flush,
Therm. disinfection |
Stagnation flush,
Therm. disinfection |
-
|
Stagnation flush
|
Stagnation flush
|
Stagnation flush,
Therm. disinfection |
Stagnation flush,
Therm. disinfection |
Stagnation flush
|
Stagnation flush,
Therm. disinfection |
Stagnation flush,
Therm. disinfection |
Pressure
|
-
|
-
|
-
|
-
|
-
|
-
|
High pressure / standard pressure
|
-
|
-
|
-
|
High pressure / standard pressure
|
High pressure / standard pressure
|
-
|
High pressure / standard pressure
|
High pressure / standard pressure
|
-
|
High pressure / standard pressure
|
Low pressure
|
High pressure / standard pressure
|
High pressure / standard pressure
|
High pressure / standard pressure
|
-
|
-
|
-
|
High pressure / standard pressure
|
High pressure / standard pressure
|
-
|
High pressure / standard pressure
|
High pressure / standard pressure
|
High pressure / standard pressure
|
High pressure / standard pressure
|
High pressure / standard pressure
|
High pressure / standard pressure
|
High pressure / standard pressure
|
Watersaving
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
Start/stop function
|
-
|
Start/stop function
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
Start/stop function
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
Start/stop function
|
Dual flush,
Single flush |
-
|
-
|
-
|
-
|
Start/stop function
|
Safety class
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
EB
|
EB
|
-
|
-
|
EB
|
-
|
EB
|
-
|
-
|
-
|
EB
|
-
|
-
|
-
|
-
|
-
|
-
|
EB
|
-
|
-
|
-
|
EB
|
EB
|
EB
|
Certificates
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
SVGW,
WELL |
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
DVGW,
Belgaqua |
-
|
-
|
-
|
-
|
-
|