Appliance inclined-seat valve COMFORT
|
WC operating panel MONTUS BOARD
|
Wash basin outlet valve QUAD PUSH OPEN
|
Combination angle valve QUICK COMFORT
|
Concealed shower LINUS D-SC-T
|
Wash basin tap MODUS EH-T
|
Concealed shower LINUS D-SC-M
|
Self-closing wash basin taps XERIS SC
|
Electronic wash basin tap PURIS E
|
Electronic wash basin tap PURIS E
|
Extension cable
|
Electronic conversion kit MONTUS
|
Electronic wash basin tap XERIS E-T
|
Electronic wash basin tap XERIS E
|
Electronic wash basin tap XERIS E
|
Electronic wash basin tap XERIS E
|
Electronic wash basin tap XERIS E-T
|
Electronic wash basin tap PURIS E
|
Concealed wash basin tap LINUS W-E-M
|
Electronic wash basin tap XERIS E
|
Electronic wash basin tap XERIS E
|
|
QUICK plug-in technology
|
Mixed water, ThermoProtect thermostat
|
HD-M - High pressure mixed water, ThermoProtect cartridge
|
Mixed water
|
HD-M mid - high-pressure mixed water
|
HD-M - high-pressure mixed water
|
ND-M - low pressure mixed water
|
HD-M mid - high-pressure mixed water, ThermoProtect thermostat
|
HD-K large - high-pressure cold water/pre-mixed water
|
HD-K small - high-pressure cold water/pre-mixed water
|
HD-K large - high-pressure cold water/pre-mixed water
|
HD-M mid - high-pressure mixed water, ThermoProtect thermostat
|
HD-M - high-pressure mixed water
|
Mixed water
|
HD-K small - high-pressure cold water/pre-mixed water
|
HD-M small - high-pressure mixed water
|
||||||
Article number
|
|||||||||||||||||||||
With COMFORT handle and grease chamber head part.
|
Dual flush. Actuation from top or from front.
|
Lockable outlet valve with pressure closure for wash basins with overflow drain.
|
With COMFORT handle and grease chamber head part. For non-detachable, pull-proof and twist-proof installation into the QUICK adapter.
|
For WBD-SC-T concealed masterbox. Manual actuation with automatic closing.
|
Compact single-lever mixer tap with lever.
|
For WBD-SC-M concealed masterbox. Manual actuation with automatic closing.
|
Manual actuation with automatic closing. Easy flow time adjustment.
|
Infrared sensor-controlled. Excluding power supply. Suitable for networking with the SCHELL SWS water management system. Configurable via SCHELL Single Control SSC. Intended for power supply via SCHELL water management system SWS or central power supply unit.
|
Infrared sensor-controlled. Battery operation. Suitable for networking with the SCHELL SWS water management system. Configurable via SCHELL Single Control SSC. For open hot water storage tanks.
|
3-pin cable, only for use as a power supply extension cable. Suitable for electronic taps in the series GRANDIS, PURIS, VENUS, XELIS and XERIS.
|
For FIELD E and FIELD H WC operating panel. In combination with a MONTUS WC module with 8 cm concealed cistern.
|
Infrared sensor-controlled. Battery operation. Suitable for networking with the SCHELL SWS water management system. Configurable via SCHELL Single Control SSC.
|
Infrared sensor-controlled. Battery operation. Suitable for networking with the SCHELL SWS water management system. Configurable via SCHELL Single Control SSC.
|
Infrared sensor-controlled. Mains operation (transformer plug). Suitable for networking with the SCHELL SWS water management system. Configurable via SCHELL Single Control SSC.
|
Infrared sensor-controlled. Mains operation (transformer plug). Suitable for networking with the SCHELL SWS water management system. Configurable via SCHELL Single Control SSC.
|
Infrared sensor-controlled. Mains operation (transformer plug). Suitable for networking with the SCHELL SWS water management system. Configurable via SCHELL Single Control SSC.
|
Infrared sensor-controlled. Mains operation (transformer plug). Suitable for networking with the SCHELL SWS water management system. Configurable via SCHELL Single Control SSC. With extended outlet 140 mm.
|
For WBW-E-M concealed masterbox. Infrared sensor-controlled. Excluding power supply. Suitable for networking with the SCHELL SWS water management system. Configurable via SCHELL Single Control SSC. Intended for power supply via SCHELL water management system SWS or central power supply unit.
|
Infrared sensor-controlled. Mains operation (concealed transformer). Suitable for networking with the SCHELL SWS water management system. Configurable via SCHELL Single Control SSC.
|
Infrared sensor-controlled. Mains operation (concealed transformer). Suitable for networking with the SCHELL SWS water management system. Configurable via SCHELL Single Control SSC.
|
|
Scope of delivery
Delivery data
|
Delivery data
|
Scope of delivery
Delivery data
|
Scope of delivery
Delivery data
|
Scope of delivery
Delivery data
|
Scope of delivery
Delivery data
|
Scope of delivery
Delivery data
|
Scope of delivery
Delivery data
|
Scope of delivery
Delivery data
|
Scope of delivery
Delivery data
|
Delivery data
|
Scope of delivery
Delivery data
|
Scope of delivery
Delivery data
|
Scope of delivery
Delivery data
|
Scope of delivery
Delivery data
|
Scope of delivery
Delivery data
|
Scope of delivery
Delivery data
|
Scope of delivery
Delivery data
|
Scope of delivery
Delivery data
|
Scope of delivery
Delivery data
|
Scope of delivery
Delivery data
|
|
Technical data
|
Technical data
|
Technical data
|
Technical data
|
Technical data
|
Technical data
|
Technical data
|
Technical data
|
Technical data
|
Technical data
|
Technical data
|
|
Technical data
|
Technical data
|
Technical data
|
Technical data
|
Technical data
|
Technical data
|
Technical data
|
Technical data
|
Technical data
|
|
Filter categories
|
|||||||||||||||||||||
Connection
|
1/2"
|
-
|
-
|
Plug-in technology
|
-
|
3/8"
|
-
|
3/8"
|
3/8"
|
3/8"
|
-
|
-
|
3/8"
|
3/8"
|
3/8"
|
3/8"
|
3/8"
|
3/8"
|
-
|
3/8"
|
3/8"
|
Outlet
|
Hose screw connection
|
-
|
-
|
3/8",
Hose screw connection, Compression connection |
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
Equipment
|
Backflow preventer
|
-
|
-
|
Backflow preventer
|
-
|
-
|
-
|
Filter,
Backflow preventer |
Backflow preventer,
Filter |
Filter,
Flow restrictor |
-
|
-
|
Backflow preventer,
Filter, Flow restrictor |
Backflow preventer,
Filter, Flow restrictor |
Backflow preventer,
Filter |
Backflow preventer,
Filter, Flow restrictor |
Backflow preventer,
Filter, Flow restrictor |
Backflow preventer,
Filter |
-
|
Backflow preventer,
Filter, Flow restrictor |
Backflow preventer,
Filter, Flow restrictor |
Safety class
|
EB
|
-
|
-
|
EB
|
-
|
EB
|
-
|
EB
|
EB
|
-
|
-
|
-
|
EB
|
EB
|
EB
|
EB
|
EB
|
EB
|
-
|
EB
|
EB
|
Function
|
-
|
Self-closing mechanical
|
-
|
-
|
Self-closing mechanical
|
Single lever
|
Self-closing mechanical
|
Self-closing mechanical
|
Contact-free,
Self-closing electronic |
Contact-free,
Self-closing electronic |
-
|
Contact-free,
Self-closing electronic |
Contact-free,
Self-closing electronic |
Contact-free,
Self-closing electronic |
Contact-free,
Self-closing electronic |
Contact-free,
Self-closing electronic |
Contact-free,
Self-closing electronic |
Contact-free,
Self-closing electronic |
Contact-free,
Self-closing electronic |
Contact-free,
Self-closing electronic |
Contact-free,
Self-closing electronic |
Temperature
|
-
|
Cold water/pre-m. water
|
-
|
-
|
Thermostat (incl. scald protection)
|
Mixed water
|
Mixed water
|
Mixed water
|
Mixed water
|
Mixed water,
Mixed water (low-pressure) |
-
|
Cold water/pre-m. water
|
Thermostat (incl. scald protection),
Mixed water |
Cold water/pre-m. water
|
Cold water/pre-m. water
|
Cold water/pre-m. water
|
Thermostat (incl. scald protection),
Mixed water |
Mixed water
|
Mixed water
|
Cold water/pre-m. water
|
Mixed water
|
Watersaving
|
-
|
Dual flush
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
Dual flush
|
-
|
Start/stop function
|
Start/stop function
|
-
|
-
|
-
|
-
|
Start/stop function
|
Start/stop function
|
Finish
|
-
|
Chrome
|
-
|
-
|
Stainless steel
|
Chrome
|
Chrome
|
Chrome
|
Chrome
|
Chrome
|
-
|
-
|
Chrome
|
Chrome
|
Chrome
|
Chrome
|
Chrome
|
Chrome
|
Chrome
|
Chrome
|
Chrome
|
Installation
|
-
|
Wet Wall installation,
Dry wall installation |
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
Hygiene
|
-
|
-
|
-
|
-
|
Therm. disinfection
|
-
|
-
|
-
|
Stagnation flush,
Therm. disinfection |
Stagnation flush
|
-
|
Stagnation flush
|
Stagnation flush,
Therm. disinfection |
Stagnation flush
|
Stagnation flush
|
Stagnation flush
|
Stagnation flush,
Therm. disinfection |
Stagnation flush
|
Stagnation flush,
Therm. disinfection |
Stagnation flush
|
Stagnation flush,
Therm. disinfection |
Pressure
|
-
|
-
|
-
|
-
|
-
|
High pressure / standard pressure
|
-
|
High pressure / standard pressure
|
High pressure / standard pressure
|
Low pressure
|
-
|
-
|
High pressure / standard pressure
|
High pressure / standard pressure
|
High pressure / standard pressure
|
High pressure / standard pressure
|
High pressure / standard pressure
|
High pressure / standard pressure
|
High pressure / standard pressure
|
High pressure / standard pressure
|
High pressure / standard pressure
|
Noises
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
Noise class 1
|
Noise class 1
|
Noise class 1
|
-
|
-
|
Noise class 1
|
Noise class 1
|
Noise class 1
|
Noise class 1
|
Noise class 1
|
Noise class 1
|
-
|
Noise class 1
|
Noise class 1
|
System solutions
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
SWS Water Management System,
Single Control SSC |
SWS Water Management System,
Single Control SSC |
-
|
-
|
SWS Water Management System,
Single Control SSC |
SWS Water Management System,
Single Control SSC |
SWS Water Management System,
Single Control SSC |
SWS Water Management System,
Single Control SSC |
SWS Water Management System,
Single Control SSC |
SWS Water Management System,
Single Control SSC |
SWS Water Management System,
Single Control SSC |
SWS Water Management System,
Single Control SSC |
SWS Water Management System,
Single Control SSC |
Energy supply
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
via SWS or central power pack
|
Battery mode
|
-
|
-
|
Battery mode
|
Battery mode
|
Mains mode
|
Mains mode
|
Mains mode
|
Mains mode
|
via SWS or central power pack
|
Mains mode
|
Mains mode
|