SWS Server
Concealed valve DN 15
Design angle valve QUAD
Electronic wash basin tap XERIS E
WC control EDITION E Manual
Electronic wash basin tap PURIS E
Flow regulator set LEED max. 1.3 l/min pressure-independent
Draw-off valve
Electronic wash basin tap XERIS E-T
Electronic wash basin tap XERIS E
Electronic wash basin tap PURIS E
Concealed WC flush valves COMPACT II
Concealed wash basin tap LINUS W-E-V
Electronic wash basin tap XERIS E-T
Electronic wash basin tap XERIS E
Electronic wash basin tap PURIS E
Electronic wash basin tap PURIS E
Electronic wash basin tap CELIS E
HD-K large - high-pressure cold water/pre-mixed water
Vandal-resistant design
HD-K - high-pressure cold water/pre-mixed water
Spray jet
HD-M mid - high-pressure mixed water, ThermoProtect thermostat
HD-K large - high-pressure cold water/pre-mixed water
HD-M - high-pressure mixed water
Cold water/pre-mixed water
HD-M mid - high-pressure mixed water, ThermoProtect thermostat
HD-M mid - high-pressure mixed water
HD-M - high-pressure mixed water
HD-K - high-pressure cold water/pre-mixed water
HD-M - high-pressure mixed water
Article number
Central computer unit for setting up a water management system and control for water-saving drinking water hygiene. Access via PC, mobile device via web app or building management system. <br> • Networking of up to 64 participants (e.g. fittings) via cable or radio (meshwork). <br> • Participants can be individually parameterised centrally. <br> • Centrally controlled stagnation flush (simultaneous). <br> - At fixed intervals and on fixed dates. <br> - When a temperature is exceeded/fallen below. - Triggered by an external signal (BMS, switch, etc.).
With shut-off and regulating function.
Covered outlet connection and covered cone compression connection for connecting flexible connection hoses/copper pipes. With sanitary grease chamber head part. According to DIN 3227.
Infrared sensor-controlled. Excluding power supply. Suitable for networking with the SCHELL SWS water management system. Configurable via SCHELL Single Control SSC. Intended for power supply via SCHELL water management system SWS or central power supply unit.
Contact-free infrared sensor flushing facility with button for manual actuation. For SCHELL COMPACT II concealed WC flush valve. Automatic triggering when leaving the WC (room monitoring). Dual flush. Suitable for networking with the SCHELL SWS water management system. Configurable via SCHELL Single Control SSC. Power supply via SWS, mains adapter or battery compartment.
Infrared sensor-controlled. Excluding power supply. Suitable for networking with the SCHELL SWS water management system. Configurable via SCHELL Single Control SSC. Intended for power supply via SCHELL water management system SWS or central power supply unit.
For all XERIS E wash basin taps. 2 LEED points when used in the public sector. 6 LEED points when used in the private sector.
Head part with grip handle. HD safety combination (EN 1717).
Infrared sensor-controlled. Battery operation. Suitable for networking with the SCHELL SWS water management system. Configurable via SCHELL Single Control SSC.
Infrared sensor-controlled. Battery operation. Suitable for networking with the SCHELL SWS water management system. Configurable via SCHELL Single Control SSC.
Infrared sensor-controlled. Battery operation. Suitable for networking with the SCHELL SWS water management system. Configurable via SCHELL Single Control SSC. With extended outlet 140 mm.
Low-noise concealed flush valve. For combination with all SCHELL WC controls/operating panels. Conform to DIN EN 12541. Internal isolating valve.
For WBW-E-V concealed masterbox. Infrared sensor-controlled. Excluding power supply. Suitable for networking with the SCHELL SWS water management system. Configurable via SCHELL Single Control SSC. Intended for power supply via SCHELL water management system SWS or central power supply unit.
Infrared sensor-controlled. Mains operation (transformer plug). Suitable for networking with the SCHELL SWS water management system. Configurable via SCHELL Single Control SSC.
Infrared sensor-controlled. Mains operation (transformer plug). Suitable for networking with the SCHELL SWS water management system. Configurable via SCHELL Single Control SSC.
Infrared sensor-controlled. Mains operation (transformer plug). Suitable for networking with the SCHELL SWS water management system. Configurable via SCHELL Single Control SSC. With extended outlet 140 mm.
Infrared sensor-controlled. Mains operation (concealed transformer). Suitable for networking with the SCHELL SWS water management system. Configurable via SCHELL Single Control SSC.
Infrared sensor-controlled. Mains operation (transformer plug). Suitable for networking with the SCHELL SWS water management system. Configurable via SCHELL Single Control SSC.

Scope of delivery

  • SWS server
    • Integrated micro SD card

Delivery data

  • Weight: 1,26 kg/Piece
  • Packing unit: 1

Scope of delivery

  • Concealed spindle valve
    • COMFORT handle
    • Non-rising head part
    • Push rod
    • Maintenance-free spindle seal
  • Protective cap
  • Push rosette Ø 65 mm

Delivery data

  • Weight: 0,35 kg/Piece
  • Packing unit: 20

Scope of delivery

  • Designer angle valve
    • Solid operating handle
    • Polished brass body
    • Grease chamber head part
    • Push rod
  • High-tensile brass cone compression connection with length compensation
  • Solid metal rosette with slide ring

Delivery data

  • Weight: 0,58 kg/Piece
  • Packing unit: 1

Scope of delivery

  • Infrared sensor single-hole tap
    • Infrared sensor electronics, programmable
    • Standpipe extension
    • 6 V axial solenoid valve with pre-filter
    • Flow regulator
    • Connection cable, 350 mm, with 3-pin plug connector, protection class IP65
  • Flexible Clean-Fix S connection hose, G 3/8 IG x 500 mm, with integrated backflow preventer (EN 1717: EB-type) and pre-filter
  • Fastening material for wash basin installation

Delivery data

  • Weight: 2,33 kg/Piece
  • Packing unit: 1

Scope of delivery

  • Front panel with infrared sensor window and button for manual actuation
  • Mechanical bypass valve for manual actuation in the event of power failure
  • 6 V solenoid valve with pre-filter
  • Self-closing cartridge with automatic nozzle cleaning needle
  • Baffle plate for flow rate regulation
  • Installation frame with infrared sensor electronics, programmable

Delivery data

  • Weight: 1,31 kg/Piece
  • Packing unit: 1

Scope of delivery

  • Infrared sensor single-hole tap
    • Infrared sensor electronics, programmable
    • 6 V solenoid valve with pre-filter
    • Flow regulator
    • Connection cable, 250 mm, with 3-pin plug connector, protection class IP65
  • Flexible Clean-Fix S connection hose, G 3/8 IG x 380 mm, with pre-filter
  • Fastening material for wash basin installation

Delivery data

  • Weight: 2,31 kg/Piece
  • Packing unit: 1

Delivery data

  • Weight: 0,04 kg/Set
  • Packing unit: 1

Scope of delivery

  • Draw-off valve
    • Grip handle
    • Backflow preventer (EN 1717: EB-type)
    • Anti-vacuum device (EN 1717: HB-type)
  • Hose screw connection

Delivery data

  • Weight: 0,35 kg/Piece
  • Packing unit: 20

Scope of delivery

  • Infrared sensor single-hole tap
    • ThermoProtect thermostat, conform to EN 1111, temperature lock (factory setting 38 °C), anti-scalding protection if cold water supply fails
    • Infrared sensor electronics, programmable
    • 6 V axial solenoid valve with pre-filter
    • Flow regulator
    • Connection cable, 220 mm, with 3-pin plug connector, protection class IP65
  • 6 V battery compartment, protection class IP65
  • 4x AA alkaline battery 1.5 V
  • 2 flexible Clean-Fix S connection hoses, G 3/8 IG x 400 mm, with integrated backflow preventer (EN 1717: EB-type) and pre-filter
  • Fastening material for wash basin installation

Delivery data

  • Weight: 2,45 kg/Piece
  • Packing unit: 1

Scope of delivery

  • Infrared sensor single-hole tap
    • Infrared sensor electronics, programmable
    • Standpipe extension
    • 6 V axial solenoid valve with pre-filter
    • Flow regulator
    • Connection cable, 350 mm, with 3-pin plug connector, protection class IP65
  • 6 V battery compartment, protection class IP65
  • 4x AA alkaline battery 1.5 V
  • Flexible Clean-Fix S connection hose, G 3/8 IG x 500 mm, with integrated backflow preventer (EN 1717: EB-type) and pre-filter
  • Fastening material for wash basin installation

Delivery data

  • Weight: 2,57 kg/Piece
  • Packing unit: 1

Scope of delivery

  • Infrared sensor single-hole tap
    • Temperature controller
    • Infrared sensor electronics, programmable
    • 6 V solenoid valve with pre-filter
    • Flow regulator
    • 6 V battery compartment (integrated)
  • 4x AAA alkaline battery 1.5 V
  • 2 flexible Clean-Fix S connection hoses, G 3/8 IG x 380 mm, with integrated backflow preventer (EN 1717: EB-type) and pre-filter
  • Fastening material for wash basin installation

Delivery data

  • Weight: 2,63 kg/Piece
  • Packing unit: 1

Scope of delivery

  • Masterbox
    • Roughing-in housing
    • Concealed flush valve COMPACT II, with isolating valve and flush plug
    • Pipe interrupter (DIN EN 12541)
  • Flush-mounted cap
  • Height-adjustable flush pipe with construction plug

Delivery data

  • Weight: 1,63 kg/Piece
  • Packing unit: 1

Scope of delivery

  • Front panel with infrared sensor window
  • Installation frame with infrared sensor electronics, programmable
  • Wall outlet with flow regulator (theft-safe)
  • Fastening material

Delivery data

  • Weight: 1,68 kg/Piece
  • Packing unit: 1

Scope of delivery

  • Infrared sensor single-hole tap
    • ThermoProtect thermostat, conform to EN 1111, temperature lock (factory setting 38 °C), anti-scalding protection if cold water supply fails
    • Infrared sensor electronics, programmable
    • 6 V axial solenoid valve with pre-filter
    • Flow regulator
    • Connection cable, 220 mm, with 3-pin plug connector, protection class IP65
  • Transformer plug 9 VDC, 100-240 VAC, 50-60 Hz
  • 2 flexible Clean-Fix S connection hoses, G 3/8 IG x 400 mm, with integrated backflow preventer (EN 1717: EB-type) and pre-filter
  • Fastening material for wash basin installation

Delivery data

  • Weight: 2,51 kg/Piece
  • Packing unit: 1

Scope of delivery

  • Infrared sensor single-hole tap
    • Temperature controller
    • Infrared sensor electronics, programmable
    • 6 V axial solenoid valve with pre-filter
    • Flow regulator
    • Connection cable, 220 mm, with 3-pin plug connector, protection class IP65
  • Transformer plug 9 VDC, 100-240 VAC, 50-60 Hz
  • 2 flexible Clean-Fix S connection hoses, G 3/8 IG x 400 mm, with integrated backflow preventer (EN 1717: EB-type) and pre-filter
  • Fastening material for wash basin installation

Delivery data

  • Weight: 1,87 kg/Piece
  • Packing unit: 1

Scope of delivery

  • Infrared sensor single-hole tap
    • Temperature controller
    • Infrared sensor electronics, programmable
    • 6 V solenoid valve with pre-filter
    • Flow regulator
  • Transformer plug 9 VDC, 100-240 VAC, 50-60 Hz
  • 2 flexible Clean-Fix S connection hoses, G 3/8 IG x 380 mm, with integrated backflow preventer (EN 1717: EB-type) and pre-filter
  • Fastening material for wash basin installation

Delivery data

  • Weight: 2,66 kg/Piece
  • Packing unit: 1

Scope of delivery

  • Infrared sensor single-hole tap
    • Infrared sensor electronics, programmable
    • 6 V solenoid valve with pre-filter
    • Flow regulator
  • Concealed transformer 9 VDC, 100-240 VAC, 50-60 Hz
  • Flexible Clean-Fix S connection hose, G 3/8 IG x 380 mm, with pre-filter
  • Fastening material for wash basin installation

Delivery data

  • Weight: 2,38 kg/Piece
  • Packing unit: 1

Scope of delivery

  • Infrared sensor single-hole tap
    • Temperature controller
    • Infrared sensor electronics, programmable
    • 6 V solenoid valve with pre-filter
    • Flow regulator
    • Connection cable, 250 mm, with 3-pin plug connector, protection class IP65
  • Transformer plug 9 VDC, 100-240 VAC, 50-60 Hz
  • 2 flexible Clean-Fix S connection hoses, G 3/8 IG x 380 mm, with integrated backflow preventer (EN 1717: EB-type) and pre-filter
  • Fastening material for wash basin installation

Delivery data

  • Weight: 1,97 kg/Piece
  • Packing unit: 1

Technical data

  • Programmable parameters (SWS server)
    • User rights management
    • Duration of flow
    • Energy saving mode
    • Trap flushing
    • Max. flow time
    • Post Runtime
    • Cleaning stop
    • Sensor range
    • Flush time
    • Stadium program
    • Stagnation flush
    • Thermal disinfection
    • Pre-flush
  • Approved according to: DIN EN 61000-6-2:2005, DIN EN 61000-6-3:2006 + A1:2010, DIN EN 61000-6-3:2007 + A1:2011, DIN EN 61000-4-2:2009, EN 300328, EN 301 489-1, EN 301 489-17, DIN EN 60950-1:2006 / A12:2011

Technical data

  • Max. Operating pressure: 10 bar
  • Max. operating temperature: 85 °C
  • Material: Brass, conform to German drinking water regulations
  • Surface: Chrome
  • Installation depth: 0 - 40 mm
  • Connection: DN 15 G 1/2 IG
  • Outlet: DN 15 G 1/2 IG
  • Certificates: P-IX 28893/II
  • Noise class: II

Technical data

  • Material: Brass, conform to German drinking water regulations
  • Surface: Chrome
  • Connection: DN 15 G 1/2 AG
  • Outlet: Ø 10 mm (DN 10 G 3/8 AG)
  • Certificates: P-IX 757/IA, ACS
  • Noise class: I
  • Flow class: A

Technical data

  • Setting options via SWS SSC
    • Sensor range (short/medium/long)
    • Programming via short range reflex (off/on)
    • Max. flow time (1-360 s)
    • Follow-up time (0.6-60 s)
    • Stagnation flush (off/5-600 s, every 1-240 h after last flush/every 1-240 h)
    • Continuous flush for thermal disinfection, with anti-scalding protection (off/15-600 s)
    • Duration of flow (off/15-600 s)
    • Energy saving mode (off/1-254 h after last flush)
    • Cleaning stop (off/60-360 s)
  • Setting options via short range reflex
    • Sensor range (short/medium/long)
    • Stagnation flush (off/30 s, every 24 h after last flush/every 24 h)
    • Continuous flush for thermal disinfection, with anti-scalding protection (off/300 s/120 s)
    • Cleaning stop (off/60 s)
  • Flow: max. 5 l/min pressure independent
  • Flow pressure: 1.0 - 5.0 bar
  • Max. Resting pressure: 8 bar
  • Max. operating temperature: 70 °C (80 °C for thermal disinfection)
  • Material: Housing Brass; Parts in contact with water Plastic
  • Surface: Chrome
  • Connection: G 3/8 IG
  • Certificates: PA-IX 29072/IO, Belgaqua
  • Noise class: I
  • Flow class: O

Technical data

  • Setting options via SWS SSC
    • Programming via short range reflex (off/on)
    • Sensor range (short/medium/long)
    • Dual flush (eco flush volume 3 l with dwell time <45 s, main flush volume 4.5/6/9 l)
    • Stagnation flush (off/5-600 s, every 1-240 h after last flush/every 1-240 h)
    • Energy saving mode (off/1-254 h after last flush)
    • Cleaning stop (off/60-360 s)
  • Setting options via short range reflex
    • Sensor range (short/medium/long)
    • Stagnation flush (off/every 24 hours after last flush)
    • Dual flush (eco flush volume 3 l with dwell time <45 s, main flush volume 4.5/6/9 l)
  • Material: Front panel Stainless steel
  • Surface: Front panel Brushed stainless steel
  • Dimensions front plate: w 120 mm x h 150 mm x d 12 mm

Technical data

  • Setting options via SWS SSC
    • Sensor range (short/medium/long)
    • Programming via short range reflex (off/on)
    • Max. flow time (1-360 s)
    • Follow-up time (0.6-60 s)
    • Stagnation flush (off/5-600 s, every 1-240 h after last flush/every 1-240 h)
    • Continuous flush for thermal disinfection, with anti-scalding protection (off/15-600 s)
    • Duration of flow (off/15-600 s)
    • Energy saving mode (off/1-254 h after last flush)
    • Cleaning stop (off/60-360 s)
  • Setting options via short range reflex
    • Sensor range (short/medium/long)
    • Stagnation flush (off/30 s, every 24 h after last flush/every 24 h)
    • Continuous flush for thermal disinfection, with anti-scalding protection (off/300 s/120 s)
    • Cleaning stop (off/60 s)
  • Flow: max. 5 l/min pressure independent
  • Flow pressure: 1.0 - 5.0 bar
  • Max. Resting pressure: 8 bar
  • Max. operating temperature: 70 °C (80 °C for thermal disinfection)
  • Material: Housing Brass, conform to German drinking water regulations
  • Surface: Chrome
  • Connection: G 3/8 IG
  • Certificates: P-IX 9523-I
  • Noise class: I

Technical data

  • Flow: max. 0,35 gpm ≈ 1,3 l/min
  • Connection: M 24 x 1 AG

Technical data

  • Material: Brass, conform to German drinking water regulations
  • Surface: Chrome
  • Connection: DN 15 G 1/2 AG
  • Outlet: Hose screw connection Ø 14.5 mm (DN 20 G 3/4 AG)
  • Safety device, conforms to EN 1717: HD
  • Certificates: PA-IX 28174/I, DIN-DVGW, ACS, Belgaqua
  • Noise class: I, at 100% flow

Technical data

  • Setting options via SWS SSC
    • Programming via short range reflex (off/on)
    • Sensor range (short/medium/long)
    • Max. flow time (1-360 s)
    • Follow-up time (0.6-60 s)
    • Stagnation flush (off/5-600 s, every 1-240 h after last flush/every 1-240 h)
    • Continuous flush for thermal disinfection, with anti-scalding protection (off/15-600 s)
    • Duration of flow (off/15-600 s)
    • Energy saving mode (off/1-254 h after last flush)
    • Cleaning stop (off/60-360 s)
  • Setting options via short range reflex
    • Sensor range (short/medium/long)
    • Stagnation flush (off/30 s, every 24 h after last flush/every 24 h)
    • Continuous flush for thermal disinfection, with anti-scalding protection (off/300 s/120 s)
    • Cleaning stop (off/60 s)
  • Thermal disinfection: possible, after releasing the temperature lock
  • Flow: max. 5 l/min pressure independent
  • Flow pressure: 1.0 - 5.0 bar
  • Max. Resting pressure: 8 bar
  • Max. operating temperature: 70 °C (80 °C for thermal disinfection)
  • Material: Housing Brass; Parts in contact with water Plastic
  • Surface: Chrome
  • Connection: 2x G 3/8 IG
  • Certificates: PA-IX 29073/IO, Belgaqua, WRAS applied
  • Noise class: I
  • Flow class: O

Technical data

  • Setting options via SWS SSC
    • Sensor range (short/medium/long)
    • Programming via short range reflex (off/on)
    • Max. flow time (1-360 s)
    • Follow-up time (0.6-60 s)
    • Stagnation flush (off/5-600 s, every 1-240 h after last flush/every 1-240 h)
    • Continuous flush for thermal disinfection, with anti-scalding protection (off/15-600 s)
    • Duration of flow (off/15-600 s)
    • Energy saving mode (off/1-254 h after last flush)
    • Cleaning stop (off/60-360 s)
  • Setting options via short range reflex
    • Sensor range (short/medium/long)
    • Stagnation flush (off/30 s, every 24 h after last flush/every 24 h)
    • Continuous flush for thermal disinfection, with anti-scalding protection (off/300 s/120 s)
    • Cleaning stop (off/60 s)
  • Flow: max. 5 l/min pressure independent
  • Flow pressure: 1.0 - 5.0 bar
  • Max. Resting pressure: 8 bar
  • Max. operating temperature: 70 °C (80 °C for thermal disinfection)
  • Material: Housing Brass; Parts in contact with water Plastic
  • Surface: Chrome
  • Certificates: PA-IX 29072/IO, Belgaqua
  • Noise class: I
  • Flow class: O

Technical data

  • Setting options via SWS SSC
    • Programming via short range reflex (off/on)
    • Sensor range (short/medium/long)
    • Max. flow time (1-360 s)
    • Stagnation flush (off/5-600 s, every 1-240 h after last flush/every 1-240 h)
    • Continuous flush for thermal disinfection, with anti-scalding protection (off/15-600 s)
    • Duration of flow (off/15-600 s)
    • Energy saving mode (off/1-254 h after last flush)
    • Cleaning stop (off/60-360 s)
  • Setting options via short range reflex
    • Sensor range (short/medium/long)
    • Stagnation flush (off/30 s, every 24 h after last flush/every 24 h)
    • Continuous flush for thermal disinfection, with anti-scalding protection (off/300 s/120 s)
    • Cleaning stop (off/60 s)
  • Flow: max. 5 l/min pressure independent
  • Flow pressure: 1.0 - 5.0 bar
  • Max. Resting pressure: 8 bar
  • Max. operating temperature: 70 °C (80 °C for thermal disinfection)
  • Material: Housing Brass, conform to German drinking water regulations
  • Surface: Chrome
  • Connection: 2x G 3/8 IG
  • Certificates: P-IX 9523-I, Belgaqua
  • Noise class: I

Technical data

  • Flow pressure: 1.2 - 5.0 bar
  • Max. Resting pressure: 8 bar
  • Flush flow: 1.0 - 1.3 l/s
  • Material: Housing Plastic; Waterpath Dezincification-resistant brass, conform to German drinking water regulations
  • Connection: DN 20 G 3/4 AG (right)
  • Outlet: Flush pipe Ø 45 mm
  • Certificates: PA-IX 18844/I, DIN-DVGW, Belgaqua
  • Noise class: I, at 100% flow

Technical data

  • Setting options via SWS SSC
    • Sensor range (short/medium/long)
    • Programming via short range reflex (off/on)
    • Max. flow time (1-360 s)
    • Follow-up time (0.6-60 s)
    • Stagnation flush (off/5-600 s, every 1-240 h after last flush/every 1-240 h)
    • Continuous flush for thermal disinfection, with anti-scalding protection (off/15-600 s)
    • Duration of flow (off/15-600 s)
    • Energy saving mode (off/1-254 h after last flush)
    • Cleaning stop (off/60-360 s)
  • Setting options via short range reflex
    • Sensor range (short/medium/long)
    • Stagnation flush (off/30 s, every 24 h after last flush/every 24 h)
    • Continuous flush for thermal disinfection, with anti-scalding protection (off/300 s/120 s)
    • Cleaning stop (off/60 s)
  • Flow: max. 5 l/min pressure independent
  • Flow pressure: 1.0 - 5.0 bar
  • Max. Resting pressure: 8 bar
  • Max. operating temperature: 70 °C (80 °C for thermal disinfection)
  • Material: Outlet Brass, conform to German drinking water regulations; Front panel Brass
  • Surface: Outlet Chrome; Front panel Chrome
  • Outlet: L 170 mm
  • Dimensions front plate: w 188 mm x h 180 mm x d 12 mm

Technical data

  • Setting options via SWS SSC
    • Programming via short range reflex (off/on)
    • Sensor range (short/medium/long)
    • Max. flow time (1-360 s)
    • Follow-up time (0.6-60 s)
    • Stagnation flush (off/5-600 s, every 1-240 h after last flush/every 1-240 h)
    • Continuous flush for thermal disinfection, with anti-scalding protection (off/15-600 s)
    • Duration of flow (off/15-600 s)
    • Energy saving mode (off/1-254 h after last flush)
    • Cleaning stop (off/60-360 s)
  • Setting options via short range reflex
    • Sensor range (short/medium/long)
    • Stagnation flush (off/30 s, every 24 h after last flush/every 24 h)
    • Continuous flush for thermal disinfection, with anti-scalding protection (off/300 s/120 s)
    • Cleaning stop (off/60 s)
  • Thermal disinfection: possible, after releasing the temperature lock
  • Flow: max. 5 l/min pressure independent
  • Flow pressure: 1.0 - 5.0 bar
  • Max. Resting pressure: 8 bar
  • Max. operating temperature: 70 °C (80 °C for thermal disinfection)
  • Material: Housing Brass; Parts in contact with water Plastic
  • Surface: Chrome
  • Connection: 2x G 3/8 IG
  • Certificates: PA-IX 29073/IO, Belgaqua
  • Noise class: I
  • Flow class: O

Technical data

  • Setting options via SWS SSC
    • Sensor range (short/medium/long)
    • Programming via short range reflex (off/on)
    • Max. flow time (1-360 s)
    • Follow-up time (0.6-60 s)
    • Stagnation flush (off/5-600 s, every 1-240 h after last flush/every 1-240 h)
    • Continuous flush for thermal disinfection, with anti-scalding protection (off/15-600 s)
    • Duration of flow (off/15-600 s)
    • Energy saving mode (off/1-254 h after last flush)
    • Cleaning stop (off/60-360 s)
  • Setting options via short range reflex
    • Sensor range (short/medium/long)
    • Stagnation flush (off/30 s, every 24 h after last flush/every 24 h)
    • Continuous flush for thermal disinfection, with anti-scalding protection (off/300 s/120 s)
    • Cleaning stop (off/60 s)
  • Flow: max. 5 l/min pressure independent
  • Flow pressure: 1.0 - 5.0 bar
  • Max. Resting pressure: 8 bar
  • Max. operating temperature: 70 °C (80 °C for thermal disinfection)
  • Material: Housing Brass; Parts in contact with water Plastic
  • Surface: Chrome
  • Certificates: PA-IX 29072/IO, Belgaqua
  • Noise class: I
  • Flow class: O

Technical data

  • Setting options via SWS SSC
    • Programming via short range reflex (off/on)
    • Sensor range (short/medium/long)
    • Max. flow time (1-360 s)
    • Stagnation flush (off/5-600 s, every 1-240 h after last flush/every 1-240 h)
    • Continuous flush for thermal disinfection, with anti-scalding protection (off/15-600 s)
    • Duration of flow (off/15-600 s)
    • Energy saving mode (off/1-254 h after last flush)
    • Cleaning stop (off/60-360 s)
  • Setting options via short range reflex
    • Sensor range (short/medium/long)
    • Stagnation flush (off/30 s, every 24 h after last flush/every 24 h)
    • Continuous flush for thermal disinfection, with anti-scalding protection (off/300 s/120 s)
    • Cleaning stop (off/60 s)
  • Flow: max. 5 l/min pressure independent
  • Flow pressure: 1.0 - 5.0 bar
  • Max. Resting pressure: 8 bar
  • Max. operating temperature: 70 °C (80 °C for thermal disinfection)
  • Material: Housing Brass, conform to German drinking water regulations
  • Surface: Chrome
  • Connection: 2x G 3/8 IG
  • Certificates: P-IX 9523-I, Belgaqua
  • Noise class: I

Technical data

  • Setting options via SWS SSC
    • Sensor range (short/medium/long)
    • Programming via short range reflex (off/on)
    • Max. flow time (1-360 s)
    • Follow-up time (0.6-60 s)
    • Stagnation flush (off/5-600 s, every 1-240 h after last flush/every 1-240 h)
    • Continuous flush for thermal disinfection, with anti-scalding protection (off/15-600 s)
    • Duration of flow (off/15-600 s)
    • Energy saving mode (off/1-254 h after last flush)
    • Cleaning stop (off/60-360 s)
  • Setting options via short range reflex
    • Sensor range (short/medium/long)
    • Stagnation flush (off/30 s, every 24 h after last flush/every 24 h)
    • Continuous flush for thermal disinfection, with anti-scalding protection (off/300 s/120 s)
    • Cleaning stop (off/60 s)
  • Flow: max. 5 l/min pressure independent
  • Flow pressure: 1.0 - 5.0 bar
  • Max. Resting pressure: 8 bar
  • Max. operating temperature: 70 °C (80 °C for thermal disinfection)
  • Material: Housing Brass, conform to German drinking water regulations
  • Surface: Chrome
  • Connection: G 3/8 IG
  • Certificates: P-IX 9523-I
  • Noise class: I

Technical data

  • Setting options via SWS SSC
    • Sensor range (short/medium/long)
    • Programming via short range reflex (off/on)
    • Max. flow time (1-360 s)
    • Follow-up time (0.6-60 s)
    • Stagnation flush (off/5-600 s, every 1-240 h after last flush/every 1-240 h)
    • Continuous flush for thermal disinfection, with anti-scalding protection (off/15-600 s)
    • Duration of flow (off/15-600 s)
    • Energy saving mode (off/1-254 h after last flush)
    • Cleaning stop (off/60-360 s)
  • Setting options via short range reflex
    • Sensor range (short/medium/long)
    • Stagnation flush (off/30 s, every 24 h after last flush/every 24 h)
    • Continuous flush for thermal disinfection, with anti-scalding protection (off/300 s/120 s)
    • Cleaning stop (off/60 s)
  • Flow: max. 5 l/min pressure independent
  • Flow pressure: 1.0 - 5.0 bar
  • Max. Resting pressure: 8 bar
  • Max. operating temperature: 70 °C (80 °C for thermal disinfection)
  • Material: Housing Brass, conform to German drinking water regulations
  • Surface: Chrome
  • Connection: 2x G 3/8 IG
  • Certificates: P-IX 19116/IZ, Belgaqua, WRAS applied
  • Noise class: I
  • Flow class: Z
Filter categories
System solutions
SWS Water Management System
-
-
SWS Water Management System,
Single Control SSC
SWS Water Management System,
Single Control SSC
SWS Water Management System,
Single Control SSC
-
-
SWS Water Management System,
Single Control SSC
SWS Water Management System,
Single Control SSC
SWS Water Management System,
Single Control SSC
SWS Water Management System,
Single Control SSC
SWS Water Management System,
Single Control SSC
SWS Water Management System,
Single Control SSC
SWS Water Management System,
Single Control SSC
SWS Water Management System,
Single Control SSC
SWS Water Management System,
Single Control SSC
SWS Water Management System,
Single Control SSC
Connection
-
-
1/2"
3/8"
-
3/8"
-
1/2"
3/8"
3/8"
3/8"
-
-
3/8"
3/8"
3/8"
3/8"
3/8"
Outlet
-
-
3/8",
Compression connection
-
-
-
-
Hose screw connection
-
-
-
-
-
-
-
-
-
-
Noises
-
-
Noise class 1
Noise class 1
-
Noise class 1
-
-
Noise class 1
Noise class 1
Noise class 1
Noise class 1
-
Noise class 1
Noise class 1
Noise class 1
Noise class 1
Noise class 1
Function
-
-
-
Contact-free,
Self-closing electronic
Contact-free,
Self-closing electronic
Contact-free,
Self-closing electronic
-
-
Contact-free,
Self-closing electronic
Contact-free,
Self-closing electronic
Contact-free,
Self-closing electronic
Contact-free,
Self-closing electronic,
Self-closing mechanical
Contact-free,
Self-closing electronic
Contact-free,
Self-closing electronic
Contact-free,
Self-closing electronic
Contact-free,
Self-closing electronic
Contact-free,
Self-closing electronic
Contact-free,
Self-closing electronic
Temperature
-
-
-
Cold water/pre-m. water
-
Cold water/pre-m. water
-
-
Thermostat (incl. scald protection),
Mixed water
Cold water/pre-m. water
Mixed water
Mixed water
Cold water/pre-m. water
Thermostat (incl. scald protection),
Mixed water
Mixed water
Mixed water
Cold water/pre-m. water
Mixed water
Watersaving
-
-
-
Start/stop function
Dual flush,
Stadium program
-
-
-
-
Start/stop function
-
Dual flush,
Single flush
-
-
Start/stop function
-
-
-
Hygiene
-
-
-
Stagnation flush
-
Stagnation flush,
Therm. disinfection
-
-
Stagnation flush,
Therm. disinfection
Stagnation flush
Stagnation flush
Stagnation flush
Stagnation flush,
Therm. disinfection
Stagnation flush,
Therm. disinfection
Stagnation flush
Stagnation flush
Stagnation flush
Stagnation flush
Energy supply
-
-
-
via SWS or central power pack
via SWS or central power pack,
Battery operation,
Mains operation
via SWS or central power pack
-
-
Battery mode
Battery mode
Battery mode
-
via SWS or central power pack
Mains mode
Mains mode
Mains mode
Mains mode
Mains mode
Finish
-
-
-
Chrome
Stainless steel
Chrome
-
-
Chrome
Chrome
Chrome
-
Chrome
Chrome
Chrome
Chrome
Chrome
Chrome
Pressure
-
-
-
High pressure / standard pressure
High pressure / standard pressure
High pressure / standard pressure
-
-
High pressure / standard pressure
High pressure / standard pressure
High pressure / standard pressure
High pressure / standard pressure
High pressure / standard pressure
High pressure / standard pressure
High pressure / standard pressure
High pressure / standard pressure
High pressure / standard pressure
High pressure / standard pressure
Equipment
-
-
-
Backflow preventer,
Filter,
Flow restrictor
-
Filter
-
Backflow preventer,
Anti-vacuum device
Backflow preventer,
Filter,
Flow restrictor
Backflow preventer,
Filter,
Flow restrictor
Filter,
Backflow preventer
-
-
Backflow preventer,
Filter,
Flow restrictor
Backflow preventer,
Filter,
Flow restrictor
Backflow preventer,
Filter
Filter
Filter,
Backflow preventer
Safety class
-
-
-
EB
-
-
-
HD
EB
EB
EB
-
-
EB
EB
EB
-
EB
Certificates
-
-
-
-
-
-
-
DVGW,
Belgaqua
-
-
WELL
DVGW,
Belgaqua
-
-
-
-
SVGW,
WELL
SVGW,
WELL
18