Flexible Clean-Fix S hose
Flexible Clean-Flex S hose
Electronic wash basin tap PURIS E
Stabilising ring
Electronic wash basin tap XERIS E
Concealed wash basin tap LINUS W-E-M
WC operating panel EDITION ND
ND-M - low pressure mixed water
HD-K small - high-pressure cold water/pre-mixed water
Mixed water
Article number
With stainless steel braided sleeving.
With stainless steel braided sleeving and a rotatable connection line.
Infrared sensor-controlled. Mains operation (concealed transformer). Suitable for networking with the SCHELL SWS water management system. Configurable via SCHELL Single Control SSC. For open hot water storage tanks.
For mounting washbasin taps on stainless steel basins.
Infrared sensor-controlled. Battery operation. Suitable for networking with the SCHELL SWS water management system. Configurable via SCHELL Single Control SSC.
For WBW-E-M concealed masterbox. Infrared sensor-controlled. Battery operation. Suitable for networking with the SCHELL SWS water management system. Configurable via SCHELL Single Control SSC.
For SCHELL COMPACT II ND concealed WC flush valve. Low pressure from 0.8 bar.

Delivery data

  • Weight: 0,11 kg/Piece
  • Packing unit: 20

Delivery data

  • Weight: 0,08 kg/Piece
  • Packing unit: 50 (loosely packed)

Scope of delivery

  • Infrared sensor single-hole tap
    • Temperature controller
    • Infrared sensor electronics, programmable
    • 6 V solenoid valve with pre-filter
    • Flow regulator
    • Connection cable, 250 mm, with 3-pin plug connector, protection class IP65
  • Concealed transformer 9 VDC, 100-240 VAC, 50-60 Hz
  • 3 flexible Clean-Fix S connection hoses, G 3/8 IG x 380/500 mm
  • Fastening material for wash basin installation

Delivery data

  • Weight: 2,56 kg/Piece
  • Packing unit: 1

Delivery data

  • Packing unit: 1

Scope of delivery

  • Infrared sensor single-hole tap
    • Infrared sensor electronics, programmable
    • 6 V axial solenoid valve with pre-filter
    • Flow regulator
    • Connection cable, 250 mm, with 3-pin plug connector, protection class IP65
  • 6 V battery compartment, protection class IP65
  • 4x AA alkaline battery 1.5 V
  • Flexible Clean-Fix S connection hose, G 3/8 IG x 400 mm, with integrated backflow preventer (EN 1717: EB-type) and pre-filter
  • Fastening material for wash basin installation

Delivery data

  • Weight: 1,73 kg/Piece
  • Packing unit: 1

Scope of delivery

  • Front panel with infrared sensor window
    • Mixed water operating button with push sleeve
  • Installation frame with infrared sensor electronics, programmable
  • 6 V battery compartment, protection class IP65
  • Fastening material

Delivery data

  • Weight: 2,02 kg/Piece
  • Packing unit: 1

Scope of delivery

  • Designer operating panel
    • Operating button
  • Low-pressure self-closing cartridge with automatic nozzle cleaning needle
  • Baffle plate for flow rate regulation
  • Installation frame

Delivery data

  • Weight: 0,62 kg/Piece
  • Packing unit: 1

Technical data

  • Surface: Connection Chrome
  • length: 500 mm
  • nominal diameter: DN 8
  • Connection: Union nut G 1/2 IG with pre-assembled seal, External thread G 1/2 AG

Technical data

  • Surface: Connection Chrome
  • length: 300 mm
  • nominal diameter: DN 8
  • Connection: High-tensile brass cone compression connection Ø 10 mm (DN 10 G 3/8 AG), Union nut G 3/8 IG with pre-assembled seal
  • Certificates: DVGW

Technical data

  • Setting options via SWS SSC
    • Sensor range (short/medium/long)
    • Programming via short range reflex (off/on)
    • Max. flow time (1-360 s)
    • Follow-up time (0.6-60 s)
    • Stagnation flush (off/5-600 s, every 1-240 h after last flush/every 1-240 h)
    • Continuous flush for thermal disinfection, with anti-scalding protection (off/15-600 s)
    • Duration of flow (off/15-600 s)
    • Energy saving mode (off/1-254 h after last flush)
    • Cleaning stop (off/60-360 s)
  • Setting options via short range reflex
    • Sensor range (short/medium/long)
    • Stagnation flush (off/30 s, every 24 h after last flush/every 24 h)
    • Continuous flush for thermal disinfection, with anti-scalding protection (off/300 s/120 s)
    • Cleaning stop (off/60 s)
  • Flow: max. 5 l/min pressure independent
  • Flow pressure: 1.0 - 5.0 bar
  • Max. Resting pressure: 8 bar
  • Max. operating temperature: 70 °C (80 °C for thermal disinfection)
  • Material: Housing Brass, conform to German drinking water regulations
  • Surface: Chrome
  • Connection: 3x G 3/8 IG
  • Certificates: P-IX 9524-I
  • Noise class: I

Technical data

  • Setting options via SWS SSC
    • Programming via short range reflex (off/on)
    • Sensor range (short/medium/long)
    • Max. flow time (1-360 s)
    • Follow-up time (0.6-60 s)
    • Stagnation flush (off/5-600 s, every 1-240 h after last flush/every 1-240 h)
    • Continuous flush for thermal disinfection, with anti-scalding protection (off/15-600 s)
    • Duration of flow (off/15-600 s)
    • Energy saving mode (off/1-254 h after last flush)
    • Cleaning stop (off/60-360 s)
  • Setting options via short range reflex
    • Sensor range (short/medium/long)
    • Stagnation flush (off/30 s, every 24 h after last flush/every 24 h)
    • Continuous flush for thermal disinfection, with anti-scalding protection (off/300 s/120 s)
    • Cleaning stop (off/60 s)
  • Flow: max. 5 l/min pressure independent
  • Flow pressure: 1.0 - 5.0 bar
  • Max. Resting pressure: 8 bar
  • Max. operating temperature: 70 °C (80 °C for thermal disinfection)
  • Material: Housing Brass; Parts in contact with water Plastic
  • Surface: Chrome
  • Connection: G 3/8 IG
  • Certificates: PA-IX 29072/IO, Belgaqua, WRAS applied
  • Noise class: I
  • Flow class: O

Technical data

  • Setting options via SWS SSC
    • Sensor range (short/medium/long)
    • Programming via short range reflex (off/on)
    • Max. flow time (1-360 s)
    • Follow-up time (0.6-60 s)
    • Stagnation flush (off/5-600 s, every 1-240 h after last flush/every 1-240 h)
    • Continuous flush for thermal disinfection, with anti-scalding protection (off/15-600 s)
    • Duration of flow (off/15-600 s)
    • Energy saving mode (off/1-254 h after last flush)
    • Cleaning stop (off/60-360 s)
  • Setting options via short range reflex
    • Sensor range (short/medium/long)
    • Stagnation flush (off/30 s, every 24 h after last flush/every 24 h)
    • Continuous flush for thermal disinfection, with anti-scalding protection (off/300 s/120 s)
    • Cleaning stop (off/60 s)
  • Flow: max. 5 l/min pressure independent
  • Flow pressure: 1.0 - 5.0 bar
  • Max. Resting pressure: 8 bar
  • Max. operating temperature: 70 °C (80 °C for thermal disinfection)
  • Material: Outlet Brass, conform to German drinking water regulations; Actuation Brass; Front panel Brass
  • Surface: Outlet Chrome; Actuation Chrome; Front panel Chrome
  • Outlet: L 170 mm
  • Dimensions front plate: w 188 mm x h 180 mm x d 12 mm

Technical data

  • Single flush: 4.5 - 6.0 l
  • Material: Actuation Plastic; Front panel Plastic
  • Surface: Actuation Alpine white; Front panel Alpine white
  • Dimensions front plate: w 124 mm x h 153.5 mm x d 12 mm
Filter categories
Connection
1/2"
3/8"
3/8"
-
3/8"
-
-
Outlet
1/2"
3/8",
Compression connection
-
-
-
-
-
Certificates
DVGW
DVGW
-
-
-
-
-
System solutions
-
-
SWS Water Management System,
Single Control SSC
-
SWS Water Management System,
Single Control SSC
SWS Water Management System,
Single Control SSC
-
Function
-
-
Contact-free,
Self-closing electronic
-
Contact-free,
Self-closing electronic
Contact-free,
Self-closing electronic
Self-closing mechanical
Temperature
-
-
Mixed water,
Mixed water (low-pressure)
-
Cold water/pre-m. water
Mixed water
-
Hygiene
-
-
Stagnation flush
-
Stagnation flush
Stagnation flush,
Therm. disinfection
-
Energy supply
-
-
Mains mode
-
Battery mode
Battery mode
-
Finish
-
-
Chrome
-
Chrome
Chrome
White
Pressure
-
-
Low pressure
-
High pressure / standard pressure
High pressure / standard pressure
Low pressure
Noises
-
-
Noise class 1
-
Noise class 1
-
Noise class 2
Equipment
-
-
Filter,
Flow restrictor
-
Backflow preventer,
Filter,
Flow restrictor
-
-
Watersaving
-
-
-
-
Start/stop function
-
Single flush
Safety class
-
-
-
-
EB
-
-
7