Angle valve with regulating function COMFORT
Electronic wash basin tap MODUS Trend E
HD-M - high-pressure mixed water
Article number
With COMFORT handle. Adjustable screw connection for high suspended cisterns.
Infrared sensor-controlled. Mains operation.

Scope of delivery

  • Angle valve (short version)
    • COMFORT handle
    • Brass compression fitting (connection)

Delivery data

  • Weight: 0,15 kg/Piece
  • Packing unit: 10

Scope of delivery

  • Infrared sensor single-hole tap
    • Temperature controller
    • Infrared sensor electronics, programmable
    • 6 V solenoid valve with pre-filter
    • Aerator
    • Connection cable, 200 mm, with 2-pin plug, protection class IP65
    • 2 flexible connection hoses, G 3/8 IG x 450 mm, with backflow preventer (DIN EN 1717: EB-type) and pre-filter
  • Transformer plug 6 VDC, 100-240 VAC, 50-60 Hz
  • Fastening material for wash basin installation

Delivery data

  • Weight: 1,71 kg/Piece
  • Packing unit: 1

Technical data

  • Material: Brass, conform to German drinking water regulations
  • Surface: Chrome
  • Connection: Brass compression fitting Ø 15 (DN 15 G 1/2 AG)
  • Outlet: Union nut DN 15 G 1/2 IG
  • Certificates: P-IX 212/IA, ACS
  • Noise class: I
  • Flow class: A

Technical data

  • Setting options via short range reflex
    • Sensor range area (approx. 2-17 cm)
    • Cleaning stop (off/120 s)
  • Flow: max. 1 gpm ≈ 3,8 l/min
  • Flow pressure: 0.5 - 5.0 bar
  • Max. Resting pressure: 8 bar
  • Max. operating temperature: 70 °C (temporarily, e.g. for thermal disinfection)
  • Material: Housing Brass, conform to German drinking water regulations
  • Surface: Chrome
  • Connection: 2x G 3/8 IG
  • Certificates: P-IX 29853/IO, WRAS applied
  • Noise class: I
  • Flow class: O
Filter categories
Connection
1/2",
Compression connection
3/8"
Outlet
1/2"
-
Temperature
-
Mixed water
Finish
-
Chrome
Pressure
-
High pressure / standard pressure
Noises
-
Noise class 1
Equipment
-
Filter,
Backflow preventer
Safety class
-
EB
Function
-
Contact-free,
Self-closing electronic
Hygiene
-
Stagnation flush
Energy supply
-
Mains mode
2