Installation element
Infrared exposed urinal flush valve SCHELLTRONIC, DN 15
Electronic wash basin tap XERIS E
T-piece
T-piece
Extension set for concealed valves
Pipe set for angle valve thermostat
Flexible Clean-Fix S hose
Electronic wash basin tap XERIS E
Benelux / France model
HD-K large - high-pressure cold water/pre-mixed water
Rigid design
HD-M mid - high-pressure mixed water
Article number
Both as construction plug and for high-precision depth compensation for all fitting connections. Annealed unstressed (540 °C/2 h).
Battery operation. Configurable via SCHELL Single Control SSC.
Infrared sensor-controlled. Excluding power supply. Suitable for networking with the SCHELL SWS water management system. Configurable via SCHELL Single Control SSC. Intended for power supply via SCHELL water management system SWS or central power supply unit.
For single tap points.
Extension 40 mm, non-rising spindle.
Pipe set for connection between angle valve G 3/8 AG and angle valve thermostat.
With stainless steel braided sleeving.
Infrared sensor-controlled. Mains operation (transformer plug). Suitable for networking with the SCHELL SWS water management system. Configurable via SCHELL Single Control SSC.

Scope of delivery

  • Installation element
    • ASAG easy (Self-sealing connection thread)
  • Sealing plug

Delivery data

  • Weight: 0,16 kg/Piece
  • Packing unit: 25

Scope of delivery

  • Exposed urinal flush valve
    • Infrared sensor electronics, programmable
    • 6 V solenoid valve with pre-filter
    • Isolating valve
  • 4x AAA alkaline battery 1.5 V
  • Urinal internal connector
  • Push rosette Ø 80 mm
  • Flush pipe Ø 15 mm x 314 mm

Delivery data

  • Weight: 1,27 kg/Piece
  • Packing unit: 1

Scope of delivery

  • Infrared sensor single-hole tap
    • Infrared sensor electronics, programmable
    • Standpipe extension
    • 6 V axial solenoid valve with pre-filter
    • Flow regulator
    • Connection cable, 350 mm, with 3-pin plug connector, protection class IP65
  • Flexible Clean-Fix S connection hose, G 3/8 IG x 500 mm, with integrated backflow preventer (EN 1717: EB-type) and pre-filter
  • Fastening material for wash basin installation

Delivery data

  • Weight: 2,33 kg/Piece
  • Packing unit: 1

Scope of delivery

  • T-piece
  • High-tensile brass cone compression connection

Delivery data

  • Weight: 0,13 kg/Piece
  • Packing unit: 1

Delivery data

  • Weight: 0,11 kg/Piece
  • Packing unit: 5

Delivery data

  • Weight: 0,10 kg/Piece
  • Packing unit: 1

Scope of delivery

  • T-piece with movable union nut G 3/8 IG
  • Connection pipe with 2 high-tensile SCHELL brass cone compression connections with length compensation

Delivery data

  • Weight: 0,16 kg/Piece
  • Packing unit: 1

Delivery data

  • Weight: 0,08 kg/Piece
  • Packing unit: 20

Scope of delivery

  • Infrared sensor single-hole tap
    • Temperature controller
    • Infrared sensor electronics, programmable
    • 6 V axial solenoid valve with pre-filter
    • Flow regulator
    • Connection cable, 220 mm, with 3-pin plug connector, protection class IP65
  • Transformer plug 9 VDC, 100-240 VAC, 50-60 Hz
  • 2 flexible Clean-Fix S connection hoses, G 3/8 IG x 400 mm, with integrated backflow preventer (EN 1717: EB-type) and pre-filter
  • Fastening material for wash basin installation

Delivery data

  • Weight: 1,87 kg/Piece
  • Packing unit: 1

Technical data

  • Material: Brass, conform to German drinking water regulations
  • Surface: Brass
  • Connection: DN 15 G 1/2 AG with ASAG easy

Technical data

  • Setting options via SSC
    • Sensor range (short/medium/long)
    • Flush time (1-15 s)
    • Stagnation flush (off/5-600 s, every 1-240 h after last flush/every 1-240 h)
    • Pre-flush (off/1 s, lockout time 5-60 min after last flush)
    • Automatic stadium program (off/1 s per user, main flush 20-60s after last use)
    • Odour trap flush (off/1-240 h after last flush)
    • Energy saving mode (off/1-254 h after last flush)
  • Setting options via short range reflex
    • Sensor range (short/medium/long)
    • Stagnation flush (off/30 s, every 24 h after last flush/every 24 h)
    • Pre-flush (off/1 s)
    • Automatic stadium program (off/1 s per user)
    • Rap flush (off/on)
    • Flush time (1-15 s)
  • Flow pressure: 1.0 - 5.0 bar
  • Flush flow: 0.3 l/s, conform to DIN EN 12541
  • Material: Parts in contact with water Brass, conform to German drinking water regulations
  • Surface: Chrome
  • Connection: DN 15 G 1/2 AG
  • Outlet: Internal connector Ø 43 mm (flush pipe Ø 15 mm)
  • Certificates: PA-IX 8952/II, Belgaqua
  • Noise class: II, at 100% flow

Technical data

  • Setting options via SWS SSC
    • Sensor range (short/medium/long)
    • Programming via short range reflex (off/on)
    • Max. flow time (1-360 s)
    • Follow-up time (0.6-60 s)
    • Stagnation flush (off/5-600 s, every 1-240 h after last flush/every 1-240 h)
    • Continuous flush for thermal disinfection, with anti-scalding protection (off/15-600 s)
    • Duration of flow (off/15-600 s)
    • Energy saving mode (off/1-254 h after last flush)
    • Cleaning stop (off/60-360 s)
  • Setting options via short range reflex
    • Sensor range (short/medium/long)
    • Stagnation flush (off/30 s, every 24 h after last flush/every 24 h)
    • Continuous flush for thermal disinfection, with anti-scalding protection (off/300 s/120 s)
    • Cleaning stop (off/60 s)
  • Flow: max. 5 l/min pressure independent
  • Flow pressure: 1.0 - 5.0 bar
  • Max. Resting pressure: 8 bar
  • Max. operating temperature: 70 °C (80 °C for thermal disinfection)
  • Material: Housing Brass; Parts in contact with water Plastic
  • Surface: Chrome
  • Connection: G 3/8 IG
  • Certificates: PA-IX 29072/IO, Belgaqua
  • Noise class: I
  • Flow class: O

Technical data

  • Material: Brass, conform to German drinking water regulations
  • Surface: Chrome
  • Connection: DN 15 G 1/2 AG
  • Outlet: DN 15 G 1/2 IG, Ø 10 mm (DN 15 G 1/2 AG)

Technical data

  • Material: Brass, conform to German drinking water regulations
  • Surface: Chrome
  • Connection: DN 15 G 1/2 AG
  • Outlet: DN 15 G 1/2 IG

Technical data

  • Material: Brass
  • Surface: Chrome

Technical data

  • Surface: Chrome
  • Connection: G 3/8 IG

Technical data

  • Surface: Connection Chrome
  • length: 400 mm
  • nominal diameter: DN 8
  • Connection: High-tensile brass cone compression connection Ø 10 mm (DN 10 G 3/8 AG), Pipe stub Ø 10 mm

Technical data

  • Setting options via SWS SSC
    • Sensor range (short/medium/long)
    • Programming via short range reflex (off/on)
    • Max. flow time (1-360 s)
    • Follow-up time (0.6-60 s)
    • Stagnation flush (off/5-600 s, every 1-240 h after last flush/every 1-240 h)
    • Continuous flush for thermal disinfection, with anti-scalding protection (off/15-600 s)
    • Duration of flow (off/15-600 s)
    • Energy saving mode (off/1-254 h after last flush)
    • Cleaning stop (off/60-360 s)
  • Setting options via short range reflex
    • Sensor range (short/medium/long)
    • Stagnation flush (off/30 s, every 24 h after last flush/every 24 h)
    • Continuous flush for thermal disinfection, with anti-scalding protection (off/300 s/120 s)
    • Cleaning stop (off/60 s)
  • Flow: max. 5 l/min pressure independent
  • Flow pressure: 1.0 - 5.0 bar
  • Max. Resting pressure: 8 bar
  • Max. operating temperature: 70 °C (80 °C for thermal disinfection)
  • Material: Housing Brass; Parts in contact with water Plastic
  • Surface: Chrome
  • Certificates: PA-IX 29072/IO, Belgaqua
  • Noise class: I
  • Flow class: O
Filter categories
Connection
1/2",
ASAG/ASAG easy,
Plug-in technology
-
3/8"
-
-
-
3/8"
-
3/8"
System solutions
-
Single Control SSC
SWS Water Management System,
Single Control SSC
-
-
-
-
-
SWS Water Management System,
Single Control SSC
Function
-
Contact-free,
Self-closing electronic
Contact-free,
Self-closing electronic
-
-
-
-
-
Contact-free,
Self-closing electronic
Hygiene
-
Stagnation flush
Stagnation flush
-
-
-
-
-
Stagnation flush
Energy supply
-
Battery mode
via SWS or central power pack
-
-
-
-
-
Mains mode
Finish
-
Chrome
Chrome
-
-
-
Chrome
-
Chrome
Noises
-
Noise class 2
Noise class 1
-
-
-
-
-
Noise class 1
Certificates
-
Belgaqua
-
-
-
-
-
DVGW
-
Temperature
-
-
Cold water/pre-m. water
-
-
-
-
-
Mixed water
Watersaving
-
-
Start/stop function
-
-
-
-
-
Start/stop function
Pressure
-
-
High pressure / standard pressure
-
-
-
-
-
High pressure / standard pressure
Equipment
-
-
Backflow preventer,
Filter,
Flow restrictor
-
-
-
-
-
Backflow preventer,
Filter,
Flow restrictor
Safety class
-
-
EB
-
-
-
-
-
EB
Outlet
-
-
-
-
-
-
-
3/8",
Compression connection
-
9