Flexible Clean-Flex S hose
WC operating panel MONTUS KONKAV
SWS Bus Extender wired BE-K Flow
Radiator screw connection
SSC Bluetooth® module
Wash basin tap MODUS EH
Wall connection elbow PURIS
QUICK adapter
QUICK extension 20 mm
SWS Bus extender cable BE-K
Extension set D-SC-T
Straight screw fitting with external thread
Self-closing wash basin taps XERIS SC
Compression - complete
Union nut
Compression screw connection - fully assembled
Electronic wash basin tap CELIS E
HD-M - high-pressure mixed water
QUICK plug-in technology
QUICK plug-in technology
HD-K small - high-pressure cold water/pre-mixed water
HD-M - high-pressure mixed water
Article number
With stainless steel braided sleeving and a rotatable connection line.
Dual flush. Actuation from top or from front.
Module for networking a solenoid valve for stagnation flush with the SWS server, wired. Transmits data between the solenoid valve and the SWS server.
According to DIN 3842 for compact radiators. Angled form.
For the wireless parametrisation of SSC-capable SCHELL fittings or for the optional extension of stagnation flushes. Access via SSC Bluetooth® app (can be downloaded from App Store, Play Store) and mobile Android or iOS devices. Usable as a tool for adjusting the fittings (module can then be removed). Or the module is left on the fitting (excepting VITUS shower fittings, SCHELLTRONIC urinal flush valves, and battery-operated PURIS E and VENUS E) and therefore enables stagnation flushes by weekday and by time of day. The last 64 stagnation flushes are stored and can be accessed via the app. This data can also be sent/exported via email as a CSV file if required. Access to the SSC Bluetooth® module is protected by an access code that can be changed individually.
Compact single-lever mixer tap with lever.
Design version.
With socket for plug element at 30° pitch. Outer diameter suitable for accommodating the push rosette. Low stress corrosion cracking due to galvanised surface and stress-free plug connection.
As an extension adapter if QUICK adapter installed too deep with QUICK connector on both sides. With socket for plug element at 30° pitch.
Module for linking an SWS subscriber to the SWS Server via a cabled network. Transfers data between SWS subscriber and SWS Server.
Extension when installation of the concealed WBD-SC-T masterbox is too deep.
Outlet with high-tensile brass cone compression connection.
Manual actuation with automatic closing. Easy flow time adjustment.
For union nut DN 10 G 3/8 IG.
without seal.
Brass cone compression connection.
Infrared sensor-controlled. Mains operation (concealed transformer). Suitable for networking with the SCHELL SWS water management system. Configurable via SCHELL Single Control SSC.

Delivery data

  • Weight: 0,11 kg/Piece
  • Packing unit: 20

Delivery data

  • Weight: 0,40 kg/Piece
  • Packing unit: 1

Scope of delivery

  • Bus-Extender cable BE-K Flow

Delivery data

  • Weight: 0,16 kg/Piece
  • Packing unit: 1

Scope of delivery

  • Radiator screw connection
    • Union nut, annealed

Delivery data

  • Weight: 0,43 kg/Piece
  • Packing unit: 25

Scope of delivery

  • SSC Bluetooth® module
    • Integrated rechargeable battery for date/time reserve power

Delivery data

  • Weight: 0,08 kg/Piece
  • Packing unit: 1

Scope of delivery

  • Single-lever single-hole tap
    • Single-lever mixer
    • Single-lever mixer ceramic cartridge with adjustable hot water and flow limitation
    • Flow regulator
  • 2 flexible Clean-Fix S connection hoses, G 3/8 IG x 440 mm, with integrated backflow preventer (EN 1717: EB-type) and pre-filter
  • Fastening material for wash basin installation

Delivery data

  • Weight: 1,74 kg/Piece
  • Packing unit: 1

Scope of delivery

  • Wall connection elbow
    • Designer cover
    • Backflow preventer (EN 1717: EB-type)

Delivery data

  • Weight: 0,19 kg/Piece
  • Packing unit: 1

Scope of delivery

  • QUICK adapter
    • Protective cap with vent pin
    • Water stop
    • ASAG easy (Self-sealing connection thread)

Delivery data

  • Weight: 0,10 kg/Piece
  • Packing unit: 20

Delivery data

  • Weight: 0,05 kg/Piece
  • Packing unit: 1

Scope of delivery

  • Bus extender cable BE-K

Delivery data

  • Weight: 0,16 kg/Piece
  • Packing unit: 1

Delivery data

  • Weight: 0,57 kg/Piece
  • Packing unit: 1

Delivery data

  • Weight: 0,05 kg/Piece
  • Packing unit: 20

Scope of delivery

  • Self-closing single-hole tap
    • Self-closing cartridge SC II
    • Flow regulator
  • Flexible Clean-Fix S connection hose, G 3/8 IG x 380 mm, with pre-filter
  • Fastening material for wash basin installation

Delivery data

  • Weight: 1,77 kg/Piece
  • Packing unit: 1

Scope of delivery

  • Locking ring (brass cone, rubber seal, base ring)

Delivery data

  • Weight: 0,001 kg/Piece
  • Packing unit: 50

Delivery data

  • Weight: 0,02 kg/Piece
  • Packing unit: 25

Scope of delivery

  • Union nut
  • Locking ring (brass cone, rubber seal, base ring)

Delivery data

  • Weight: 0,01 kg/Piece
  • Packing unit: 25

Scope of delivery

  • Infrared sensor single-hole tap
    • Temperature controller
    • Infrared sensor electronics, programmable
    • 6 V solenoid valve with pre-filter
    • Flow regulator
    • Connection cable, 250 mm, with 3-pin plug connector, protection class IP65
  • Concealed transformer 9 VDC, 100-240 VAC, 50-60 Hz
  • 2 flexible Clean-Fix S connection hoses, G 3/8 IG x 380 mm, with integrated backflow preventer (EN 1717: EB-type) and pre-filter
  • Fastening material for wash basin installation

Delivery data

  • Weight: 1,80 kg/Piece
  • Packing unit: 1

Technical data

  • Surface: Connection Chrome
  • length: 500 mm
  • nominal diameter: DN 8
  • Connection: 2x union nut G 3/8 IG with pre-assembled seal

Technical data

  • Material: Plastic
  • Surface: Front panel Chrome
  • Dimensions front plate: w 230 mm x h 150 mm x d 9 mm

Technical data

  • Max. Operating pressure: 10 bar
  • Max. operating temperature: 90 °C
  • Material: Brass
  • Surface: Brass
  • Connection: DN 25 G 1 IG
  • Outlet: DN 25 R 1 AG with ex worked thread

Technical data

  • Wireless standard: Bluetooth® SMART
  • Frequency band: 2,4 GHz
  • Max. Range: 10 m (depending on installation site and building materials)

Technical data

  • Flow: max. 5 l/min pressure independent
  • Flow pressure: 1.0 - 5.0 bar
  • Max. Resting pressure: 8 bar
  • Max. operating temperature: 70 °C (80 °C for thermal disinfection)
  • Material: Actuation Die-cast zinc; Housing Brass, conform to German drinking water regulations
  • Surface: Chrome
  • Connection: 2x G 3/8 IG
  • Certificates: P-IX 29002/IO, DIN-DVGW, Belgaqua
  • Noise class: I
  • Flow class: O

Technical data

  • Material: Housing Plastic; Parts in contact with water Brass, conform to German drinking water regulations
  • Surface: Chrome
  • Connection: DN 15 G 1/2 AG with ASAG easy
  • Outlet: DN 15 G 1/2 AG
  • Safety device, conforms to EN 1717: EB

Technical data

  • Material: Brass, conform to German drinking water regulations
  • Surface: Chrome
  • shaft length: 55 mm
  • Connection: DN 15 G 1/2 AG with ASAG easy
  • Outlet: QUICK plug-in technology DN 15

Technical data

  • Material: Brass, conform to German drinking water regulations
  • Surface: Chrome
  • extension by: 20 mm
  • Connection: QUICK plug-in technology DN 15
  • Outlet: QUICK plug-in technology DN 15

Technical data

  • Material: Brass
  • Surface: Chrome
  • extension by: 50 mm

Technical data

  • Material: Brass, conform to German drinking water regulations
  • Surface: Chrome
  • Connection: DN 15 G 1/2 AG
  • Outlet: Ø 10 mm (DN 10 G 3/8 AG)

Technical data

  • Running time: 2 - 15 s (7 s )
  • Flow: max. 5 l/min pressure independent
  • Flow pressure: 1.0 - 5.0 bar
  • Max. Resting pressure: 8 bar
  • Max. operating temperature: 70 °C (80 °C for thermal disinfection)
  • Material: Housing Brass, conform to German drinking water regulations
  • Surface: Chrome
  • Connection: G 3/8 IG
  • Certificates: PA-IX 29071/IO
  • Noise class: I
  • Flow class: O

Technical data

  • Connection: Ø 10

Technical data

  • Material: Brass
  • Surface: Chrome
  • Connection: Ø 14, DN 15 G 1/2 IG

Technical data

  • Material: Union nut Brass
  • Surface: Chrome
  • Connection: Ø 12, DN 10 G 3/8 IG

Technical data

  • Setting options via SWS SSC
    • Sensor range (short/medium/long)
    • Programming via short range reflex (off/on)
    • Max. flow time (1-360 s)
    • Follow-up time (0.6-60 s)
    • Stagnation flush (off/5-600 s, every 1-240 h after last flush/every 1-240 h)
    • Continuous flush for thermal disinfection, with anti-scalding protection (off/15-600 s)
    • Duration of flow (off/15-600 s)
    • Energy saving mode (off/1-254 h after last flush)
    • Cleaning stop (off/60-360 s)
  • Setting options via short range reflex
    • Sensor range (short/medium/long)
    • Stagnation flush (off/30 s, every 24 h after last flush/every 24 h)
    • Continuous flush for thermal disinfection, with anti-scalding protection (off/300 s/120 s)
    • Cleaning stop (off/60 s)
  • Flow: max. 5 l/min pressure independent
  • Flow pressure: 1.0 - 5.0 bar
  • Max. Resting pressure: 8 bar
  • Max. operating temperature: 70 °C (80 °C for thermal disinfection)
  • Material: Housing Brass, conform to German drinking water regulations
  • Surface: Chrome
  • Connection: 2x G 3/8 IG
  • Certificates: P-IX 19116/IZ, Belgaqua
  • Noise class: I
  • Flow class: Z
Filter categories
Connection
3/8"
-
-
-
-
3/8"
1/2",
ASAG/ASAG easy
1/2",
ASAG/ASAG easy,
Plug-in technology
Plug-in technology
-
-
1/2"
3/8"
-
-
-
-
Outlet
3/8"
-
-
-
-
-
1/2"
-
-
-
-
3/8",
Compression connection
-
-
-
-
3/8"
Certificates
DVGW
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
WELL
Function
-
Self-closing mechanical
-
-
-
Single lever
-
-
-
-
-
-
Self-closing mechanical
-
-
-
Contact-free,
Self-closing electronic
Temperature
-
Cold water/pre-m. water
-
-
-
Mixed water
-
-
-
-
-
-
Cold water/pre-m. water
-
-
-
Mixed water
Watersaving
-
Dual flush
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Finish
-
Chrome
-
-
-
Chrome
-
-
-
-
-
-
Chrome
-
-
-
Chrome
Installation
-
Wet Wall installation,
Dry wall installation
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
System solutions
-
-
SWS Water Management System
-
Single Control SSC
-
-
-
-
SWS Water Management System
-
-
-
-
-
-
SWS Water Management System,
Single Control SSC
Energy supply
-
-
via SWS or central power pack,
Mains operation
-
-
-
-
-
-
via SWS or central power pack,
Mains operation
-
-
-
-
-
-
Mains mode
Pressure
-
-
-
-
-
High pressure / standard pressure
-
-
-
-
-
-
High pressure / standard pressure
-
-
-
High pressure / standard pressure
Safety class
-
-
-
-
-
EB
-
-
-
-
-
-
-
-
-
-
EB
Equipment
-
-
-
-
-
-
Backflow preventer
-
-
-
-
-
Filter,
Flow restrictor
-
-
-
Filter,
Backflow preventer
Noises
-
-
-
-
-
-
-
-
-
-
-
-
Noise class 1
-
-
-
Noise class 1
Hygiene
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Stagnation flush
17