Flexible Clean-Flex S hose
Flexible Clean-Fix S hose
Flexible Clean-Flex S hose
Flexible Clean-Flex S hose
Flexible Clean-Flex S hose
Flexible Clean-Flex S hose
Flexible Clean-Flex S hose
WC operating panel MONTUS TOWER
Wall connection elbow PURIS
Exposed shower tap VITUS VD -SC-M / o
Exposed shower tap VITUS VD -EH-M / o
Straight double screw connection
Electronic kitchen tap GRANDIS E
Self-closing wash basin tap PETIT SC
Copper pipe Ø 10 mm
Flexible Clean-Fix S hose
Concealed WC flush valves COMPACT II
Electronic wash basin tap XERIS E
Compression screw connection - fully assembled
Mixed water
Mixed water
HD-M - high-pressure mixed water
HD-K - high-pressure cold water/pre-mixed water
HD-K mid. - high-pressure cold water/pre-mixed water
Article number
With stainless steel braided sleeving and a rotatable connection line.
With stainless steel braided sleeving.
With stainless steel braided sleeving and a rotatable connection line.
With stainless steel braided sleeving and a rotatable connection line.
With stainless steel braided sleeving and a rotatable connection line.
With stainless steel braided sleeving and a rotatable connection line.
With stainless steel braided sleeving and a rotatable connection line.
Dual flush. Actuation from top or from front.
Design version.
Manual actuation with automatic closing. Easy flow time adjustment. Shower connection at top.
Manual open/closed actuation. Shower connection at top.
With 2 high-tensile brass cone compression connections.
Infrared sensor-controlled. Additional single-lever operation. Battery operation. Suitable for networking with the SCHELL SWS water management system. Configurable via SCHELL Single Control SSC. Stagnation flushing in the mixing ratio of the touch-free actuation, independent of the single-lever position.
Manual actuation with automatic closing. Easy flow time adjustment.
Smooth on both ends.
With stainless steel braided sleeving.
Low-noise concealed flush valve. For combination with all SCHELL WC controls/operating panels. Conform to DIN EN 12541. Internal isolating valve.
Infrared sensor-controlled. Mains operation (concealed transformer). Suitable for networking with the SCHELL SWS water management system. Configurable via SCHELL Single Control SSC.
Brass cone compression connection.

Delivery data

  • Weight: 0,12 kg/Piece
  • Packing unit: 20

Delivery data

  • Weight: 0,08 kg/Piece
  • Packing unit: 20

Delivery data

  • Weight: 0,13 kg/Piece
  • Packing unit: 20

Delivery data

  • Weight: 0,06 kg/Piece
  • Packing unit: 20

Delivery data

  • Weight: 0,11 kg/Piece
  • Packing unit: 20

Delivery data

  • Weight: 0,08 kg/Piece
  • Packing unit: 50 (loosely packed)

Delivery data

  • Weight: 0,06 kg/Piece
  • Packing unit: 20

Delivery data

  • Weight: 0,38 kg/Piece
  • Packing unit: 1

Scope of delivery

  • Wall connection elbow
    • Designer cover
    • Backflow preventer (EN 1717: EB-type)

Delivery data

  • Weight: 0,19 kg/Piece
  • Packing unit: 1

Scope of delivery

  • Self-closing exposed shower tap
    • SC-M self-closing button
    • Self-closing cartridge SC II with hot water restrictor
    • 2 backflow preventers (EN 1717: EB-type)
  • 2 S-connections and rosettes (depth-adjustable)

Delivery data

  • Weight: 3,75 kg/Piece
  • Packing unit: 1

Scope of delivery

  • Single-lever exposed shower tap
    • Single-lever mixer
    • Single-lever mixing ceramic cartridge with hot water and flow restrictor
  • 2 backflow preventers (EN 1717: EB-type)
  • 2 S-connections and rosettes (depth-adjustable)

Delivery data

  • Weight: 3,95 kg/Piece
  • Packing unit: 1

Delivery data

  • Weight: 0,05 kg/Piece
  • Packing unit: 20

Scope of delivery

  • Infrared sensor kitchen tap
    • Single-lever mixer
    • Infrared sensor electronics, programmable
    • 6 V solenoid valve with pre-filter
    • Ceramic cartridge with hot water restrictor
    • Pivoting outlet with configurable pivot range
    • Flow regulator
    • 2 flexible connection hoses, G 3/8 IG x 450 mm, with backflow preventer (DIN EN 1717: EB-type) and pre-filter
  • 6 V battery compartment, protection class IP65
  • 4x AA alkaline battery 1.5 V

Delivery data

  • Weight: 3,76 kg/Piece
  • Packing unit: 1

Scope of delivery

  • Self-closing single-hole tap
    • Self-closing cartridge SC II
    • Flow regulator
  • Fastening material for wash basin installation

Delivery data

  • Weight: 1,00 kg/Piece
  • Packing unit: 10

Delivery data

  • Weight: 0,09 kg/Piece
  • Packing unit: 20

Delivery data

  • Weight: 0,13 kg/Piece
  • Packing unit: 20

Scope of delivery

  • Masterbox
    • Roughing-in housing
    • Concealed flush valve COMPACT II, with isolating valve and flush plug
    • Pipe interrupter (DIN EN 12541)
  • Flush-mounted cap
  • Height-adjustable flush pipe with construction plug

Delivery data

  • Weight: 1,63 kg/Piece
  • Packing unit: 1

Scope of delivery

  • Infrared sensor single-hole tap
    • Infrared sensor electronics, programmable
    • 6 V axial solenoid valve with pre-filter
    • Flow regulator
    • Connection cable, 220 mm, with 3-pin plug connector, protection class IP65
  • Concealed transformer 9 VDC, 100-240 VAC, 50-60 Hz
  • Flexible Clean-Fix S connection hose, G 3/8 IG x 400 mm, with integrated backflow preventer (EN 1717: EB-type) and pre-filter
  • Fastening material for wash basin installation

Delivery data

  • Weight: 1,82 kg/Piece
  • Packing unit: 1

Scope of delivery

  • Union nut
  • Locking ring (brass cone, rubber seal, base ring)

Delivery data

  • Weight: 0,03 kg/Piece
  • Packing unit: 20

Technical data

  • Surface: Connection Chrome
  • length: 500 mm
  • nominal diameter: DN 8
  • Connection: Union nut G 1/2 IG with pre-assembled seal, Union nut G 3/8 IG with pre-assembled seal

Technical data

  • Surface: Connection Chrome
  • length: 300 mm
  • nominal diameter: DN 8
  • Connection: Union nut G 1/2 IG with pre-assembled seal, Union nut G 3/8 IG with pre-assembled seal

Technical data

  • Surface: Connection Chrome
  • length: 500 mm
  • nominal diameter: DN 8
  • Connection: High-tensile brass cone compression connection Ø 8 mm (DN 10 G 3/8 AG), Union nut G 3/8 IG with pre-assembled seal

Technical data

  • Surface: Connection Chrome
  • length: 300 mm
  • nominal diameter: DN 8
  • Connection: Union nut G 1/2 IG with pre-assembled seal, Pipe stub Ø 10 mm

Technical data

  • Surface: Connection Chrome
  • length: 500 mm
  • nominal diameter: DN 8
  • Connection: Union nut G 1/2 IG with pre-assembled seal, Pipe stub Ø 10 mm

Technical data

  • Surface: Connection Chrome
  • length: 500 mm
  • nominal diameter: DN 8
  • Connection: High-tensile brass cone compression connection Ø 10 mm (DN 10 G 3/8 AG), Pipe stub Ø 10 mm

Technical data

  • Surface: Connection Chrome
  • length: 150 mm
  • nominal diameter: DN 8
  • Connection: Union nut G 3/8 IG with pre-assembled seal, Pipe stub Ø 10 mm

Technical data

  • Material: Plastic
  • Surface: Front panel Chrome
  • Dimensions front plate: w 230 mm x h 150 mm x d 6.5 mm

Technical data

  • Material: Housing Plastic; Parts in contact with water Brass, conform to German drinking water regulations
  • Surface: Chrome
  • Connection: DN 15 G 1/2 AG with ASAG easy
  • Outlet: DN 15 G 1/2 AG
  • Safety device, conforms to EN 1717: EB

Technical data

  • Running time: 5 - 30 s
  • Max. operating temperature: 70 °C (80 °C for thermal disinfection)
  • Material: Housing Brass, conform to German drinking water regulations
  • Surface: Chrome
  • Connection: 2x DN 15 G 1/2 AG
  • Outlet: DN 15 G 1/2 AG (top)
  • Certificates: PA-IX 38241/IB, Belgaqua
  • Noise class: I
  • Flow class: B

Technical data

  • Max. operating temperature: 70 °C (80 °C for thermal disinfection)
  • Material: Housing Brass, conform to German drinking water regulations
  • Surface: Chrome
  • Connection: 2x DN 15 G 1/2 AG
  • Outlet: DN 15 G 1/2 AG (top)
  • Certificates: PA-IX 38242/IB, Belgaqua
  • Noise class: I
  • Flow class: B

Technical data

  • Material: Brass, conform to German drinking water regulations
  • Connection: Ø 10 mm (DN 10 G 3/8 AG)
  • Outlet: Ø 10 mm (DN 10 G 3/8 AG)

Technical data

  • Tap hole diameter: 35 - 37 mm
  • Setting options via SWS SSC
    • Programming via short range reflex (off/on)
    • Max. flow time (1-600 s)
    • Stagnation flush (off/5-600 s, every 1-240 h after last flush/every 1-240 h)
    • Energy saving mode (off/1-254 h after last flush)
  • Setting options via short range reflex
    • Max. flow time (4-240 s, 12 program stages)
    • Stagnation flush (off/after last flush/fixed interval)
  • Flow: max. 10 l/min (manual activation)
  • Flow: max. 8.5 l/min (electronic activation)
  • Flow pressure: 1.0 - 5.0 bar
  • Max. Resting pressure: 8 bar
  • Max. operating temperature: 70 °C (80 °C for thermal disinfection)
  • Material: Housing Brass, conform to German drinking water regulations
  • Surface: Chrome
  • Connection: 2x G 3/8 IG
  • Certificates: P-IX 29861/IO, WRAS
  • Noise class: I
  • Flow class: O

Technical data

  • Running time: 2 - 15 s (7 s )
  • Flow: max. 5 l/min pressure independent
  • Flow pressure: 1.0 - 5.0 bar
  • Max. Resting pressure: 8 bar
  • Max. operating temperature: 70 °C (80 °C for thermal disinfection)
  • Material: Housing Brass, conform to German drinking water regulations
  • Surface: Chrome
  • Connection: DN 15 G 1/2 AG
  • Certificates: P-IX 19958/IO, DIN-DVGW, WRAS
  • Noise class: I
  • Flow class: O

Technical data

  • Surface: Chrome
  • length: 500 mm

Technical data

  • Surface: Connection Chrome
  • length: 1000 mm
  • nominal diameter: DN 8
  • Connection: High-tensile brass cone compression connection Ø 10 mm (DN 10 G 3/8 AG), Pipe stub Ø 10 mm

Technical data

  • Flow pressure: 1.2 - 5.0 bar
  • Max. Resting pressure: 8 bar
  • Flush flow: 1.0 - 1.3 l/s
  • Material: Housing Plastic; Waterpath Dezincification-resistant brass, conform to German drinking water regulations
  • Connection: DN 20 G 3/4 AG (right)
  • Outlet: Flush pipe Ø 45 mm
  • Certificates: PA-IX 18844/I, DIN-DVGW, Belgaqua
  • Noise class: I, at 100% flow

Technical data

  • Setting options via SWS SSC
    • Sensor range (short/medium/long)
    • Programming via short range reflex (off/on)
    • Max. flow time (1-360 s)
    • Follow-up time (0.6-60 s)
    • Stagnation flush (off/5-600 s, every 1-240 h after last flush/every 1-240 h)
    • Continuous flush for thermal disinfection, with anti-scalding protection (off/15-600 s)
    • Duration of flow (off/15-600 s)
    • Energy saving mode (off/1-254 h after last flush)
    • Cleaning stop (off/60-360 s)
  • Setting options via short range reflex
    • Sensor range (short/medium/long)
    • Stagnation flush (off/30 s, every 24 h after last flush/every 24 h)
    • Continuous flush for thermal disinfection, with anti-scalding protection (off/300 s/120 s)
    • Cleaning stop (off/60 s)
  • Flow: max. 5 l/min pressure independent
  • Flow pressure: 1.0 - 5.0 bar
  • Max. Resting pressure: 8 bar
  • Max. operating temperature: 70 °C (80 °C for thermal disinfection)
  • Material: Housing Brass; Parts in contact with water Plastic
  • Surface: Chrome
  • Certificates: PA-IX 29072/IO, Belgaqua
  • Noise class: I
  • Flow class: O

Technical data

  • Material: Union nut Brass
  • Surface: Chrome
  • Connection: Ø 14, DN 15 G 1/2 IG
Filter categories
Connection
3/8"
3/8"
3/8"
-
-
-
-
-
1/2",
ASAG/ASAG easy
-
-
3/8",
Compression connection
3/8"
1/2"
-
-
-
3/8"
-
Outlet
1/2"
1/2"
3/8",
Compression connection
1/2"
1/2"
3/8",
Compression connection
3/8"
-
1/2"
-
-
3/8",
Compression connection
-
-
-
3/8",
Compression connection
-
-
-
Certificates
DVGW
DVGW
DVGW
DVGW
DVGW
DVGW
DVGW
-
-
-
-
-
-
DVGW,
WRAS
-
DVGW
DVGW,
Belgaqua
-
-
Function
-
-
-
-
-
-
-
Self-closing mechanical
-
Self-closing mechanical
Single lever
-
Single lever,
Contact-free,
Self-closing electronic
Self-closing mechanical
-
-
Contact-free,
Self-closing electronic,
Self-closing mechanical
Contact-free,
Self-closing electronic
-
Temperature
-
-
-
-
-
-
-
Cold water/pre-m. water
-
Mixed water
Mixed water
-
Mixed water
Cold water/pre-m. water
-
-
Mixed water
Cold water/pre-m. water
-
Watersaving
-
-
-
-
-
-
-
Dual flush
-
-
-
-
-
-
-
-
Dual flush,
Single flush
-
-
Finish
-
-
-
-
-
-
-
Chrome
-
Chrome
Chrome
-
Chrome
Chrome
-
-
-
Chrome
-
Installation
-
-
-
-
-
-
-
Wet Wall installation,
Dry wall installation
-
-
-
-
-
-
-
-
-
-
-
Equipment
-
-
-
-
-
-
-
-
Backflow preventer
-
-
-
Filter,
Backflow preventer
-
-
-
-
Backflow preventer,
Filter,
Flow restrictor
-
System solutions
-
-
-
-
-
-
-
-
-
-
-
-
SWS Water Management System,
Single Control SSC
-
-
-
SWS Water Management System,
Single Control SSC
SWS Water Management System,
Single Control SSC
-
Hygiene
-
-
-
-
-
-
-
-
-
-
-
-
Stagnation flush,
Therm. disinfection
-
-
-
Stagnation flush
Stagnation flush
-
Energy supply
-
-
-
-
-
-
-
-
-
-
-
-
Battery mode,
Battery operation
-
-
-
-
Mains mode
-
Pressure
-
-
-
-
-
-
-
-
-
-
-
-
High pressure / standard pressure
High pressure / standard pressure
-
-
High pressure / standard pressure
High pressure / standard pressure
-
Noises
-
-
-
-
-
-
-
-
-
-
-
-
Noise class 1
Noise class 1
-
-
Noise class 1
Noise class 1
-
Safety class
-
-
-
-
-
-
-
-
-
-
-
-
EB
-
-
-
-
EB
-
19