WC operating panel MONTUS BOARD
Electronic wash basin tap PURIS E
Electronic wash basin tap PURIS E
ND-M - low pressure mixed water
HD-K - high-pressure cold water/pre-mixed water
Article number
Dual flush. Actuation from top or from front.
Infrared sensor-controlled. Battery operation. Suitable for networking with the SCHELL SWS water management system. Configurable via SCHELL Single Control SSC. For open hot water storage tanks.
Infrared sensor-controlled. Mains operation (transformer plug). Suitable for networking with the SCHELL SWS water management system. Configurable via SCHELL Single Control SSC.

Delivery data

  • Weight: 0,40 kg/Piece
  • Packing unit: 1

Scope of delivery

  • Infrared sensor single-hole tap
    • Temperature controller
    • Infrared sensor electronics, programmable
    • 6 V solenoid valve with pre-filter
    • Flow regulator
    • 6 V battery compartment (integrated)
  • 4x AAA alkaline battery 1.5 V
  • Pre-filter with flow restrictor
  • 3 flexible Clean-Fix S connection hoses, G 3/8 IG x 380/500 mm
  • Fastening material for wash basin installation

Delivery data

  • Weight: 2,38 kg/Piece
  • Packing unit: 1

Scope of delivery

  • Infrared sensor single-hole tap
    • Infrared sensor electronics, programmable
    • 6 V solenoid valve with pre-filter
    • Flow regulator
  • Transformer plug 9 VDC, 100-240 VAC, 50-60 Hz
  • Flexible Clean-Fix S connection hose, G 3/8 IG x 380 mm, with pre-filter
  • Fastening material for wash basin installation

Delivery data

  • Weight: 2,58 kg/Piece
  • Packing unit: 1

Technical data

  • Material: Plastic
  • Surface: Front panel Chrome
  • Dimensions front plate: w 230 mm x h 150 mm x d 6.5 mm

Technical data

  • Setting options via SWS SSC
    • Sensor range (short/medium/long)
    • Programming via short range reflex (off/on)
    • Max. flow time (1-360 s)
    • Follow-up time (0.6-60 s)
    • Stagnation flush (off/5-600 s, every 1-240 h after last flush/every 1-240 h)
    • Continuous flush for thermal disinfection, with anti-scalding protection (off/15-600 s)
    • Duration of flow (off/15-600 s)
    • Energy saving mode (off/1-254 h after last flush)
    • Cleaning stop (off/60-360 s)
  • Setting options via short range reflex
    • Sensor range (short/medium/long)
    • Stagnation flush (off/30 s, every 24 h after last flush/every 24 h)
    • Continuous flush for thermal disinfection, with anti-scalding protection (off/300 s/120 s)
    • Cleaning stop (off/60 s)
  • Flow: max. 5 l/min pressure independent
  • Flow pressure: 1.0 - 5.0 bar
  • Max. operating temperature: 70 °C (80 °C for thermal disinfection)
  • Material: Housing Brass, conform to German drinking water regulations
  • Surface: Chrome
  • Connection: 3x G 3/8 IG
  • Certificates: P-IX 9524-I
  • Noise class: I

Technical data

  • Setting options via SWS SSC
    • Sensor range (short/medium/long)
    • Programming via short range reflex (off/on)
    • Max. flow time (1-360 s)
    • Follow-up time (0.6-60 s)
    • Stagnation flush (off/5-600 s, every 1-240 h after last flush/every 1-240 h)
    • Continuous flush for thermal disinfection, with anti-scalding protection (off/15-600 s)
    • Duration of flow (off/15-600 s)
    • Energy saving mode (off/1-254 h after last flush)
    • Cleaning stop (off/60-360 s)
  • Setting options via short range reflex
    • Sensor range (short/medium/long)
    • Stagnation flush (off/30 s, every 24 h after last flush/every 24 h)
    • Continuous flush for thermal disinfection, with anti-scalding protection (off/300 s/120 s)
    • Cleaning stop (off/60 s)
  • Flow: max. 5 l/min pressure independent
  • Flow pressure: 1.0 - 5.0 bar
  • Max. Resting pressure: 8 bar
  • Max. operating temperature: 70 °C (80 °C for thermal disinfection)
  • Material: Housing Brass, conform to German drinking water regulations
  • Surface: Chrome
  • Connection: G 3/8 IG
  • Certificates: P-IX 9523-I, WRAS applied
  • Noise class: I
Filter categories
Function
Self-closing mechanical
Contact-free,
Self-closing electronic
Contact-free,
Self-closing electronic
Temperature
Cold water/pre-m. water
Mixed water,
Mixed water (low-pressure)
Cold water/pre-m. water
Watersaving
Dual flush
-
-
Finish
Chrome
Chrome
Chrome
Installation
Wet Wall installation,
Dry wall installation
-
-
System solutions
-
SWS Water Management System,
Single Control SSC
SWS Water Management System,
Single Control SSC
Connection
-
3/8"
3/8"
Hygiene
-
Stagnation flush
Stagnation flush
Energy supply
-
Battery mode
Mains mode
Pressure
-
Low pressure
High pressure / standard pressure
Noises
-
Noise class 1
Noise class 1
Equipment
-
Filter,
Flow restrictor
Filter
Certificates
-
-
SVGW,
WELL
3