Design angle valve QUAD
Electronic wash basin tap XERIS E
Electronic wash basin tap PURIS E
Draw-off valve
Electronic wash basin tap XERIS E
HD-K large - high-pressure cold water/pre-mixed water
HD-K - high-pressure cold water/pre-mixed water
HD-K large - high-pressure cold water/pre-mixed water
Article number
Covered outlet connection and covered cone compression connection for connecting flexible connection hoses/copper pipes. With sanitary grease chamber head part. According to DIN 3227.
Infrared sensor-controlled. Excluding power supply. Suitable for networking with the SCHELL SWS water management system. Configurable via SCHELL Single Control SSC. Intended for power supply via SCHELL water management system SWS or central power supply unit.
Infrared sensor-controlled. Excluding power supply. Suitable for networking with the SCHELL SWS water management system. Configurable via SCHELL Single Control SSC. Intended for power supply via SCHELL water management system SWS or central power supply unit.
Head part with grip handle. HD safety combination (EN 1717).
Infrared sensor-controlled. Battery operation. Suitable for networking with the SCHELL SWS water management system. Configurable via SCHELL Single Control SSC.

Scope of delivery

  • Designer angle valve
    • Solid operating handle
    • Polished brass body
    • Grease chamber head part
    • Push rod
  • High-tensile brass cone compression connection with length compensation
  • Solid metal rosette with slide ring

Delivery data

  • Weight: 0,58 kg/Piece
  • Packing unit: 1

Scope of delivery

  • Infrared sensor single-hole tap
    • Infrared sensor electronics, programmable
    • Standpipe extension
    • 6 V axial solenoid valve with pre-filter
    • Flow regulator
    • Connection cable, 350 mm, with 3-pin plug connector, protection class IP65
  • Flexible Clean-Fix S connection hose, G 3/8 IG x 500 mm, with integrated backflow preventer (EN 1717: EB-type) and pre-filter
  • Fastening material for wash basin installation

Delivery data

  • Weight: 2,33 kg/Piece
  • Packing unit: 1

Scope of delivery

  • Infrared sensor single-hole tap
    • Infrared sensor electronics, programmable
    • 6 V solenoid valve with pre-filter
    • Flow regulator
    • Connection cable, 250 mm, with 3-pin plug connector, protection class IP65
  • Flexible Clean-Fix S connection hose, G 3/8 IG x 380 mm, with pre-filter
  • Fastening material for wash basin installation

Delivery data

  • Weight: 2,31 kg/Piece
  • Packing unit: 1

Scope of delivery

  • Draw-off valve
    • Grip handle
    • Backflow preventer (EN 1717: EB-type)
    • Anti-vacuum device (EN 1717: HB-type)
  • Hose screw connection

Delivery data

  • Weight: 0,35 kg/Piece
  • Packing unit: 20

Scope of delivery

  • Infrared sensor single-hole tap
    • Infrared sensor electronics, programmable
    • Standpipe extension
    • 6 V axial solenoid valve with pre-filter
    • Flow regulator
    • Connection cable, 350 mm, with 3-pin plug connector, protection class IP65
  • 6 V battery compartment, protection class IP65
  • 4x AA alkaline battery 1.5 V
  • Flexible Clean-Fix S connection hose, G 3/8 IG x 500 mm, with integrated backflow preventer (EN 1717: EB-type) and pre-filter
  • Fastening material for wash basin installation

Delivery data

  • Weight: 2,57 kg/Piece
  • Packing unit: 1

Technical data

  • Material: Brass, conform to German drinking water regulations
  • Surface: Chrome
  • Connection: DN 15 G 1/2 AG
  • Outlet: Ø 10 mm (DN 10 G 3/8 AG)
  • Certificates: P-IX 757/IA, ACS
  • Noise class: I
  • Flow class: A

Technical data

  • Setting options via SWS SSC
    • Sensor range (short/medium/long)
    • Programming via short range reflex (off/on)
    • Max. flow time (1-360 s)
    • Follow-up time (0.6-60 s)
    • Stagnation flush (off/5-600 s, every 1-240 h after last flush/every 1-240 h)
    • Continuous flush for thermal disinfection, with anti-scalding protection (off/15-600 s)
    • Duration of flow (off/15-600 s)
    • Energy saving mode (off/1-254 h after last flush)
    • Cleaning stop (off/60-360 s)
  • Setting options via short range reflex
    • Sensor range (short/medium/long)
    • Stagnation flush (off/30 s, every 24 h after last flush/every 24 h)
    • Continuous flush for thermal disinfection, with anti-scalding protection (off/300 s/120 s)
    • Cleaning stop (off/60 s)
  • Flow: max. 5 l/min pressure independent
  • Flow pressure: 1.0 - 5.0 bar
  • Max. Resting pressure: 8 bar
  • Max. operating temperature: 70 °C (80 °C for thermal disinfection)
  • Material: Housing Brass; Parts in contact with water Plastic
  • Surface: Chrome
  • Connection: G 3/8 IG
  • Certificates: PA-IX 29072/IO, Belgaqua
  • Noise class: I
  • Flow class: O

Technical data

  • Setting options via SWS SSC
    • Sensor range (short/medium/long)
    • Programming via short range reflex (off/on)
    • Max. flow time (1-360 s)
    • Follow-up time (0.6-60 s)
    • Stagnation flush (off/5-600 s, every 1-240 h after last flush/every 1-240 h)
    • Continuous flush for thermal disinfection, with anti-scalding protection (off/15-600 s)
    • Duration of flow (off/15-600 s)
    • Energy saving mode (off/1-254 h after last flush)
    • Cleaning stop (off/60-360 s)
  • Setting options via short range reflex
    • Sensor range (short/medium/long)
    • Stagnation flush (off/30 s, every 24 h after last flush/every 24 h)
    • Continuous flush for thermal disinfection, with anti-scalding protection (off/300 s/120 s)
    • Cleaning stop (off/60 s)
  • Flow: max. 5 l/min pressure independent
  • Flow pressure: 1.0 - 5.0 bar
  • Max. Resting pressure: 8 bar
  • Max. operating temperature: 70 °C (80 °C for thermal disinfection)
  • Material: Housing Brass, conform to German drinking water regulations
  • Surface: Chrome
  • Connection: G 3/8 IG
  • Certificates: P-IX 9523-I
  • Noise class: I

Technical data

  • Material: Brass, conform to German drinking water regulations
  • Surface: Chrome
  • Connection: DN 15 G 1/2 AG
  • Outlet: Hose screw connection Ø 14.5 mm (DN 20 G 3/4 AG)
  • Safety device, conforms to EN 1717: HD
  • Certificates: PA-IX 28174/I, DIN-DVGW, ACS, Belgaqua
  • Noise class: I, at 100% flow

Technical data

  • Setting options via SWS SSC
    • Sensor range (short/medium/long)
    • Programming via short range reflex (off/on)
    • Max. flow time (1-360 s)
    • Follow-up time (0.6-60 s)
    • Stagnation flush (off/5-600 s, every 1-240 h after last flush/every 1-240 h)
    • Continuous flush for thermal disinfection, with anti-scalding protection (off/15-600 s)
    • Duration of flow (off/15-600 s)
    • Energy saving mode (off/1-254 h after last flush)
    • Cleaning stop (off/60-360 s)
  • Setting options via short range reflex
    • Sensor range (short/medium/long)
    • Stagnation flush (off/30 s, every 24 h after last flush/every 24 h)
    • Continuous flush for thermal disinfection, with anti-scalding protection (off/300 s/120 s)
    • Cleaning stop (off/60 s)
  • Flow: max. 5 l/min pressure independent
  • Flow pressure: 1.0 - 5.0 bar
  • Max. Resting pressure: 8 bar
  • Max. operating temperature: 70 °C (80 °C for thermal disinfection)
  • Material: Housing Brass; Parts in contact with water Plastic
  • Surface: Chrome
  • Certificates: PA-IX 29072/IO, Belgaqua
  • Noise class: I
  • Flow class: O
Filter categories
Connection
1/2"
3/8"
3/8"
1/2"
3/8"
Outlet
3/8",
Compression connection
-
-
Hose screw connection
-
Noises
Noise class 1
Noise class 1
Noise class 1
-
Noise class 1
System solutions
-
SWS Water Management System,
Single Control SSC
SWS Water Management System,
Single Control SSC
-
SWS Water Management System,
Single Control SSC
Function
-
Contact-free,
Self-closing electronic
Contact-free,
Self-closing electronic
-
Contact-free,
Self-closing electronic
Temperature
-
Cold water/pre-m. water
Cold water/pre-m. water
-
Cold water/pre-m. water
Watersaving
-
Start/stop function
-
-
Start/stop function
Hygiene
-
Stagnation flush
Stagnation flush,
Therm. disinfection
-
Stagnation flush
Energy supply
-
via SWS or central power pack
via SWS or central power pack
-
Battery mode
Finish
-
Chrome
Chrome
-
Chrome
Pressure
-
High pressure / standard pressure
High pressure / standard pressure
-
High pressure / standard pressure
Equipment
-
Backflow preventer,
Filter,
Flow restrictor
Filter
Backflow preventer,
Anti-vacuum device
Backflow preventer,
Filter,
Flow restrictor
Safety class
-
EB
-
HD
EB
Certificates
-
-
-
DVGW,
Belgaqua
-
5