|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||
AC double valve COMFORT
|
Double connection angle valve COMFORT
|
WC operating panel MONTUS FIELD
|
Wash basin outlet valve OPEN
|
Angle valve with regulating function COMFORT with filter
|
SSC Bluetooth® module
|
Wash basin tap MODUS EH
|
Exposed wash basin tap WALIS E
|
Sampling pipe for sampling valves
|
Concealed shower LINUS Basic D-C-T
|
SWS Temperature contact sensor PT 1000
|
Electronic wash basin tap PURIS E
|
Pressure limiter set
|
SWS Gateway BACnet IP/MSTP - X
|
Electronic wash basin tap PURIS E
|
Electronic wash basin tap MODUS Trend E
|
Tap hole rosette PETIT SC
|
Solenoid valve thermal disinfection SWS
|
Exposed shower tap VITUS VD -SC-T /u
|
Exposed shower tap VITUS VD -SC-M /u
|
WC control EDITION E Manual
|
Exposed shower tap VITUS VD -C-T / u
|
Exposed shower tap VITUS VD -C-T / u
|
Electronic kitchen tap GRANDISÂ E
|
Soap tray shower panel LINUS
|
Pipe set shower panel connection
|
Self-closing wash basin taps XERIS SC
|
Self-closing wash basin taps XERIS SC
|
Electronic wash basin tap PURIS E
|
Electronic wash basin tap PURIS E
|
Additional briefing of the SWS responsible
|
Shower head COMFORT Flex
|
Exposed wash basin tap PETIT SC
|
Exposed wash basin tap VITUS VW-C-T
|
Exposed wash basin tap VITUS VW-C-T
|
Exposed wash basin tap VITUS VW-C-T
|
Exposed wash basin tap VITUS VW-E-T
|
Angle valve thermostat set
|
Exposed wash basin tap VITUS VW-SC-M
|
Flow regulator set LEED max. 1.3 l/min pressure-independent
|
Exposed wash basin tap VITUS VW-C-T
|
Draw-off valve
|
Exposed wash basin tap VITUS VW-E-T
|
Concealed wash basin tap LINUS W-E-V
|
Electronic wash basin tap XERIS E-T
|
Electronic wash basin tap XERIS E
|
Electronic wash basin tap XERIS E
|
Electronic wash basin tap XERIS E
|
Electronic wash basin tap XERIS E
|
Electronic wash basin tap PURIS E
|
Electronic wash basin tap PURIS E
|
Concealed wash basin tap LINUS W-E-M
|
Electronic wash basin tap XERIS E
|
Electronic wash basin tap CELIS E
|
Concealed wash basin tap LINUS W-E-V
|
Shower panel LINUS DP-C-T
|
Concealed wash basin tap LINUS W-E-M
|
|
HD-M - high-pressure mixed water
|
Cold water/pre-mixed water
|
Mixed water, ThermoProtect thermostat
|
ND-M - low pressure mixed water
|
For MODUS EH-T
|
HD-K - high-pressure cold water/pre-mixed water
|
HD-K - high-pressure cold water/pre-mixed water
|
Bistable, 6 V
|
Mixed water, ThermoProtect thermostat
|
Mixed water
|
Vandal-resistant design
|
Mixed water, ThermoProtect thermostat
|
Mixed water, ThermoProtect thermostat
|
HD-M - high-pressure mixed water
|
HD-M mid - high-pressure mixed water
|
HD-K mid. - high-pressure cold water/pre-mixed water
|
HD-K - high-pressure cold water/pre-mixed water
|
HD-M - high-pressure mixed water
|
Cold water/pre-mixed water
|
Mixed water, ThermoProtect thermostat
|
Mixed water, ThermoProtect thermostat
|
Mixed water, ThermoProtect thermostat
|
Mixed water, ThermoProtect thermostat
|
Flexible design
|
Mixed water
|
Spray jet
|
Mixed water, ThermoProtect thermostat
|
Mixed water, ThermoProtect thermostat
|
Cold water/pre-mixed water
|
HD-M mid - high-pressure mixed water, ThermoProtect thermostat
|
HD-K large - high-pressure cold water/pre-mixed water
|
HD-K large - high-pressure cold water/pre-mixed water
|
HD-M small - high-pressure mixed water
|
HD-M mid - high-pressure mixed water
|
HD-K - high-pressure cold water/pre-mixed water
|
HD-M - high-pressure mixed water
|
Mixed water
|
HD-K mid. - high-pressure cold water/pre-mixed water
|
HD-M - high-pressure mixed water
|
Cold water/pre-mixed water
|
Mixed water, ThermoProtect thermostat
|
Mixed water
|
||||||||||||||||
Article number
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Auxiliary connection double valve. With COMFORT handles and grease chamber head parts.
|
Angle valve with integrated appliance valve for connecting household appliances. Actuation of angle valve under cover cap.
|
Dual flush. Actuation from top or from front. Vandal-resistant, zinc die-cast version.
|
Non-lockable outlet valve G 1 1/4 AG universal. For wash basins.
|
With COMFORT handle. To protect high-quality fittings, e.g. electronically controlled fittings. According to DIN 3227.
|
For the wireless parametrisation of SSC-capable SCHELL fittings or for the optional extension of stagnation flushes. Access via SSC Bluetooth® app (can be downloaded from App Store, Play Store) and mobile Android or iOS devices. Usable as a tool for adjusting the fittings (module can then be removed). Or the module is left on the fitting (excepting VITUS shower fittings, SCHELLTRONIC urinal flush valves, and battery-operated PURIS E and VENUS E) and therefore enables stagnation flushes by weekday and by time of day. The last 64 stagnation flushes are stored and can be accessed via the app. This data can also be sent/exported via email as a CSV file if required. Access to the SSC Bluetooth® module is protected by an access code that can be changed individually.
|
Compact single-lever mixer tap with design lever.
|
Infrared sensor-controlled. Battery operation. Suitable for networking with the SCHELL SWS water management system. Configurable via SCHELL Single Control SSC. Connection from rear or, with optional mounting frame, from top, bottom or sides.
|
For drawing off drinking water samples (DIN ISO 19458). Actuation of angle valve under cover cap.
|
For WBD-E-T concealed masterbox. Triggering via CVD-Touch electronics with automatic closing. Optional battery or mains operation. Suitable for networking with the SCHELL SWS water management system. Configurable via SCHELL Single Control SSC.
|
Temperature contact sensor for use with SWS water management system. Connection to SWS BE-K wired bus extender or SWS BE-F wireless bus extender.
|
Infrared sensor-controlled. Battery operation. Suitable for networking with the SCHELL SWS water management system. Configurable via SCHELL Single Control SSC. For open hot water storage tanks. With extended outlet 140 mm.
|
For reducing the pressure level of the cold water supply for Modus EH-T to 1 bar. Supports the function of the thermostat-safe MODUS EH-T cartridge in case of highly varying pressure conditions.
|
For integrating the SWS water management system with a central building control/automation system. Translates the SWS protocol into the BACnet IP/MSTP bus protocol. 2 seperate networks for the SWS and BACnet protocol. Data points can be chosen as required – subsequent upgrade possible to max. 2,500 data points without replacing hardware. Configuration accessible only via individual password.
|
Infrared sensor-controlled. Battery operation. Suitable for networking with the SCHELL SWS water management system. Configurable via SCHELL Single Control SSC.
|
Infrared sensor-controlled. Battery operation.
|
For wash basins with tap hole that is too large.
|
Bistable 6 V solenoid valve for thermal disinfection with SCHELL SWS water management system. Solenoid valve can be retrofitted to the planned connection in the water path. Function: Hot water is routed to bypass the thermostatic valve. Selectable via SWS BE-K wired bus extender or SWS BE-F wireless bus extender.
|
Manual actuation with automatic closing. Easy flow time adjustment. Shower connection at bottom.
|
Manual actuation with automatic closing. Easy flow time adjustment. Shower connection at bottom.
|
Contact-free infrared sensor flushing facility with button for manual actuation. For SCHELL COMPACT II concealed WC flush valve. Automatic triggering when leaving the WC (room monitoring). Dual flush. Suitable for networking with the SCHELL SWS water management system. Configurable via SCHELL Single Control SSC. Power supply via SWS, mains adapter or battery compartment.
|
Triggering via CVD-Touch electronics with automatic closing. Battery operation. Shower connection at bottom. Suitable for networking with the SCHELL SWS water management system. Configurable via SCHELL Single Control SSC.
|
Triggering via CVD-Touch electronics with automatic closing. Battery operation. Shower connection at bottom. Suitable for networking with the SCHELL SWS water management system. Configurable via SCHELL Single Control SSC.
|
Infrared sensor-controlled. Additional single-lever operation. Battery operation. Suitable for networking with the SCHELL SWS water management system. Configurable via SCHELL Single Control SSC. Stagnation flushing in the mixing ratio of the touch-free actuation, independent of the single-lever position.
|
Soap tray for all SCHELL LINUS shower panels (aluminium), for subsequent installation.
|
For exposed connections from above.
|
Manual actuation with automatic closing. Easy flow time adjustment.
|
Manual actuation with automatic closing. Easy flow time adjustment.
|
Infrared sensor-controlled. Excluding power supply. Suitable for networking with the SCHELL SWS water management system. Configurable via SCHELL Single Control SSC. Intended for power supply via SCHELL water management system SWS or central power supply unit. With extended outlet 140 mm.
|
Infrared sensor-controlled. Battery operation. Suitable for networking with the SCHELL SWS water management system. Configurable via SCHELL Single Control SSC.
|
Separate appointment excl. callout costs.
|
Adjustable tilt angle. Vandal-resistant shower head, with soft stream and anti-limescale burls. Angled version minimises likelihood of use for suicide.
|
Manual actuation with automatic closing. Easy flow time adjustment.
|
Triggering via CVD-Touch electronics with automatic closing. Battery operation. With integrated SWS BE-F VITUS wireless bus extender for networking with the SWS water management system.
|
Triggering via CVD-Touch electronics with automatic closing. Battery operation. With integrated SWS BE-F VITUS wireless bus extender for networking with the SWS water management system.
|
Triggering via CVD-Touch electronics with automatic closing. Battery operation. With integrated SWS BE-F VITUS wireless bus extender for networking with the SWS water management system.
|
Infrared sensor-controlled. Battery operation. With integrated SWS BE-F VITUS wireless bus extender for networking with the SWS water management system.
|
Thermostatic anti-scalding protection fitting incl. flexible connecting set for installation on angle valves with G 3/8 AG outlet. Setting of max. draw-off temperature, concealed under cover cap, only possible with tool.
|
Manual actuation with automatic closing. Easy flow time adjustment.
|
For all SCHELL wash basin taps PURIS, VENUS, CELIS, MODUS and PETIT. Not suitable for low pressure taps. 2 LEED points when used in the public sector. 6 LEED points when used in the private sector.
|
Triggering via CVD-Touch electronics with automatic closing. Battery operation. Suitable for networking with the SCHELL SWS water management system. Configurable via SCHELL Single Control SSC.
|
Head part with grip handle.
|
Infrared sensor-controlled. Battery operation. Suitable for networking with the SCHELL SWS water management system. Configurable via SCHELL Single Control SSC.
|
For WBW-E-V concealed masterbox. Infrared sensor-controlled. Battery operation. Suitable for networking with the SCHELL SWS water management system. Configurable via SCHELL Single Control SSC.
|
Infrared sensor-controlled. Battery operation. Suitable for networking with the SCHELL SWS water management system. Configurable via SCHELL Single Control SSC.
|
Infrared sensor-controlled. Battery operation. Suitable for networking with the SCHELL SWS water management system. Configurable via SCHELL Single Control SSC.
|
Infrared sensor-controlled. Mains operation (transformer plug). Suitable for networking with the SCHELL SWS water management system. Configurable via SCHELL Single Control SSC.
|
Infrared sensor-controlled. Mains operation (transformer plug). Suitable for networking with the SCHELL SWS water management system. Configurable via SCHELL Single Control SSC.
|
Infrared sensor-controlled. Mains operation (transformer plug). Suitable for networking with the SCHELL SWS water management system. Configurable via SCHELL Single Control SSC.
|
Infrared sensor-controlled. Mains operation (concealed transformer). Suitable for networking with the SCHELL SWS water management system. Configurable via SCHELL Single Control SSC.
|
Infrared sensor-controlled. Mains operation (concealed transformer). Suitable for networking with the SCHELL SWS water management system. Configurable via SCHELL Single Control SSC.
|
For WBW-E-M concealed masterbox. Infrared sensor-controlled. Battery operation. Suitable for networking with the SCHELL SWS water management system. Configurable via SCHELL Single Control SSC.
|
Infrared sensor-controlled. Mains operation (concealed transformer). Suitable for networking with the SCHELL SWS water management system. Configurable via SCHELL Single Control SSC.
|
Infrared sensor-controlled. Mains operation (concealed transformer). Suitable for networking with the SCHELL SWS water management system. Configurable via SCHELL Single Control SSC.
|
For WBW-E-V concealed masterbox. Infrared sensor-controlled. Mains operation. Suitable for networking with the SCHELL SWS water management system. Configurable via SCHELL Single Control SSC.
|
Made from a strong extruded aluminium profile with a high-quality, anodised finish. Triggering via CVD-Touch electronics with automatic closing. Optional battery or mains operation. Suitable for networking with the SCHELL SWS water management system. Configurable via SCHELL Single Control SSC. Pivoting front panel for easy installation and servicing. Suitable for connections from rear or for exposed connections from above.
|
For WBW-E-M concealed masterbox. Infrared sensor-controlled. Battery operation. Suitable for networking with the SCHELL SWS water management system. Configurable via SCHELL Single Control SSC.
|
|
Scope of delivery
Delivery data
|
Scope of delivery
Delivery data
|
Delivery data
|
Scope of delivery
Delivery data
|
Scope of delivery
Delivery data
|
Scope of delivery
Delivery data
|
Scope of delivery
Delivery data
|
Scope of delivery
Delivery data
|
Scope of delivery
Delivery data
|
Scope of delivery
Delivery data
|
Scope of delivery
Delivery data
|
Scope of delivery
Delivery data
|
Scope of delivery
Delivery data
|
Scope of delivery
Delivery data
|
Scope of delivery
Delivery data
|
Scope of delivery
Delivery data
|
Scope of delivery
Delivery data
|
Scope of delivery
Delivery data
|
Scope of delivery
Delivery data
|
Scope of delivery
Delivery data
|
Scope of delivery
Delivery data
|
Scope of delivery
Delivery data
|
Scope of delivery
Delivery data
|
Scope of delivery
Delivery data
|
Scope of delivery
Delivery data
|
Scope of delivery
Delivery data
|
Scope of delivery
Delivery data
|
Scope of delivery
Delivery data
|
Scope of delivery
Delivery data
|
Scope of delivery
Delivery data
|
|
Scope of delivery
Delivery data
|
Scope of delivery
Delivery data
|
Scope of delivery
Delivery data
|
Scope of delivery
Delivery data
|
Scope of delivery
Delivery data
|
Scope of delivery
Delivery data
|
Scope of deliveryAngle valve thermostat (09 414 06 99)
Delivery data
|
Scope of delivery
Delivery data
|
Scope of delivery
Delivery data
|
Scope of delivery
Delivery data
|
Scope of delivery
Delivery data
|
Scope of delivery
Delivery data
|
Scope of delivery
Delivery data
|
Scope of delivery
Delivery data
|
Scope of delivery
Delivery data
|
Scope of delivery
Delivery data
|
Scope of delivery
Delivery data
|
Scope of delivery
Delivery data
|
Scope of delivery
Delivery data
|
Scope of delivery
Delivery data
|
Scope of delivery
Delivery data
|
Scope of delivery
Delivery data
|
Scope of delivery
Delivery data
|
Scope of delivery
Delivery data
|
Scope of delivery
Delivery data
|
Scope of delivery
Delivery data
|
|
Technical data
|
Technical data
|
Technical data
|
Technical data
|
Technical data
|
Technical data
|
Technical data
|
Technical data
|
Technical data
|
Technical data
|
Technical data
|
Technical data
|
Technical data
|
Technical data
|
Technical data
|
Technical data
|
|
|
Technical data
|
Technical data
|
Technical data
|
Technical data
|
Technical data
|
Technical data
|
Technical data
|
Technical data
|
Technical data
|
Technical data
|
Technical data
|
Technical data
|
|
Technical data
|
Technical data
|
Technical data
|
Technical data
|
Technical data
|
Technical data
|
Technical dataAngle valve thermostat (09 414 06 99)
|
Technical data
|
Technical data
|
Technical data
|
Technical data
|
Technical data
|
Technical data
|
Technical data
|
Technical data
|
Technical data
|
Technical data
|
Technical data
|
Technical data
|
Technical data
|
Technical data
|
Technical data
|
Technical data
|
Technical data
|
Technical data
|
Technical data
|
|
Filter categories
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Connection
|
1/2"
|
1/2",
ASAG/ASAG easy |
-
|
-
|
1/2",
ASAG/ASAG easy |
-
|
3/8"
|
1/2"
|
1/2",
ASAG/ASAG easy |
-
|
-
|
3/8"
|
-
|
-
|
3/8"
|
3/8"
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
3/8"
|
-
|
-
|
3/8"
|
3/8"
|
3/8"
|
3/8"
|
-
|
1/2"
|
-
|
1/2"
|
1/2"
|
1/2"
|
-
|
3/8"
|
-
|
-
|
-
|
1/2"
|
-
|
-
|
3/8"
|
3/8"
|
3/8"
|
3/8"
|
3/8"
|
3/8"
|
3/8"
|
-
|
3/8"
|
-
|
-
|
1/2"
|
-
|
Outlet
|
1/2",
Hose screw connection |
3/8",
Hose screw connection, Compression connection |
-
|
-
|
3/8",
Compression connection |
-
|
-
|
-
|
3/8",
Compression connection |
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
3/8"
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
3/8"
|
-
|
1/2"
|
-
|
Equipment
|
Backflow preventer
|
Backflow preventer
|
-
|
-
|
Filter
|
-
|
-
|
-
|
-
|
-
|
-
|
Filter,
Flow restrictor |
-
|
-
|
Filter
|
Filter
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
Filter,
Backflow preventer |
-
|
-
|
Filter,
Backflow preventer |
Filter
|
Filter
|
Filter,
Backflow preventer |
-
|
-
|
-
|
Backflow preventer
|
Backflow preventer
|
Backflow preventer
|
Backflow preventer,
Flow restrictor |
Filter,
Backflow preventer |
-
|
-
|
-
|
-
|
Backflow preventer,
Flow restrictor |
-
|
Backflow preventer,
Filter, Flow restrictor |
Backflow preventer,
Filter, Flow restrictor |
Backflow preventer,
Filter, Flow restrictor |
Backflow preventer,
Filter, Flow restrictor |
Backflow preventer,
Filter, Flow restrictor |
Filter
|
Filter,
Backflow preventer |
-
|
Backflow preventer,
Filter, Flow restrictor |
Filter,
Backflow preventer |
-
|
Backflow preventer,
Filter |
-
|
Safety class
|
EB
|
EB
|
-
|
-
|
-
|
-
|
EB
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
EB
|
-
|
-
|
EB
|
-
|
-
|
EB
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
EB
|
-
|
-
|
-
|
-
|
-
|
-
|
EB
|
EB
|
EB
|
EB
|
EB
|
-
|
EB
|
-
|
EB
|
EB
|
-
|
-
|
-
|
Function
|
-
|
-
|
Self-closing mechanical
|
-
|
-
|
-
|
Single lever
|
Contact-free,
Self-closing electronic |
-
|
Self-closing electronic
|
-
|
Contact-free,
Self-closing electronic |
-
|
-
|
Contact-free,
Self-closing electronic |
Contact-free,
Self-closing electronic |
-
|
-
|
Self-closing mechanical
|
Self-closing mechanical
|
Contact-free,
Self-closing electronic |
Self-closing electronic
|
Self-closing electronic
|
Single lever,
Contact-free, Self-closing electronic |
-
|
-
|
Self-closing mechanical
|
Self-closing mechanical
|
Contact-free,
Self-closing electronic |
Contact-free,
Self-closing electronic |
-
|
-
|
Self-closing mechanical
|
Self-closing electronic
|
Self-closing electronic
|
Self-closing electronic
|
Contact-free,
Self-closing electronic |
-
|
Self-closing mechanical
|
-
|
Self-closing electronic
|
-
|
Contact-free,
Self-closing electronic |
Contact-free,
Self-closing electronic |
Contact-free,
Self-closing electronic |
Contact-free,
Self-closing electronic |
Contact-free,
Self-closing electronic |
Contact-free,
Self-closing electronic |
Contact-free,
Self-closing electronic |
Contact-free,
Self-closing electronic |
Contact-free,
Self-closing electronic |
Contact-free,
Self-closing electronic |
Contact-free,
Self-closing electronic |
Contact-free,
Self-closing electronic |
Contact-free,
Self-closing electronic |
Self-closing electronic
|
Contact-free,
Self-closing electronic |
Temperature
|
-
|
-
|
Cold water/pre-m. water
|
-
|
-
|
-
|
Mixed water
|
Cold water/pre-m. water
|
-
|
Thermostat (incl. scald protection)
|
-
|
Mixed water,
Mixed water (low-pressure) |
-
|
-
|
Cold water/pre-m. water
|
Cold water/pre-m. water
|
-
|
-
|
Thermostat (incl. scald protection),
Mixed water |
Mixed water
|
-
|
Thermostat (incl. scald protection),
Mixed water |
Thermostat (incl. scald protection),
Mixed water |
Mixed water
|
-
|
-
|
Mixed water
|
Cold water/pre-m. water
|
Cold water/pre-m. water
|
Mixed water
|
-
|
-
|
Cold water/pre-m. water
|
Thermostat (incl. scald protection)
|
Thermostat (incl. scald protection)
|
Thermostat (incl. scald protection)
|
Thermostat (incl. scald protection),
Mixed water |
Thermostat (incl. scald protection)
|
Mixed water
|
-
|
Thermostat (incl. scald protection),
Mixed water |
-
|
Thermostat (incl. scald protection),
Mixed water |
Cold water/pre-m. water
|
Thermostat (incl. scald protection),
Mixed water |
Cold water/pre-m. water
|
Cold water/pre-m. water
|
Mixed water
|
Mixed water
|
Cold water/pre-m. water
|
Mixed water
|
Mixed water
|
Cold water/pre-m. water
|
Mixed water
|
Cold water/pre-m. water
|
Thermostat (incl. scald protection),
Mixed water |
Mixed water
|
Watersaving
|
-
|
-
|
Dual flush
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
Dual flush,
Stadium program |
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
Start/stop function
|
Start/stop function
|
Start/stop function
|
-
|
-
|
-
|
-
|
Stadium program
|
-
|
-
|
-
|
-
|
Start/stop function
|
-
|
Start/stop function
|
Start/stop function
|
-
|
-
|
-
|
-
|
-
|
-
|
Start/stop function
|
-
|
Finish
|
-
|
-
|
Chrome
|
-
|
Chrome
|
-
|
Chrome
|
Chrome
|
-
|
Stainless steel
|
-
|
Chrome
|
-
|
-
|
Chrome
|
Chrome
|
-
|
-
|
Chrome
|
Chrome
|
Stainless steel
|
Chrome
|
Chrome
|
Chrome
|
-
|
-
|
Chrome
|
Chrome
|
Chrome
|
Chrome
|
-
|
Chrome
|
-
|
Chrome
|
Chrome
|
Chrome
|
Chrome
|
Chrome
|
Chrome
|
-
|
Chrome
|
-
|
Chrome
|
Chrome
|
Chrome
|
Chrome
|
Chrome
|
Chrome
|
Chrome
|
Chrome
|
Chrome
|
Chrome
|
Chrome
|
Chrome
|
Stainless steel
|
Aluminium
|
Stainless steel
|
Installation
|
-
|
-
|
Wet Wall installation,
Dry wall installation |
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
Noises
|
-
|
-
|
-
|
-
|
Noise class 1
|
-
|
-
|
-
|
Noise class 1
|
-
|
-
|
Noise class 1
|
-
|
-
|
Noise class 1
|
Noise class 1
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
Noise class 1
|
-
|
-
|
Noise class 1
|
Noise class 1
|
Noise class 1
|
Noise class 1
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
Noise class 1
|
-
|
Noise class 1
|
Noise class 1
|
Noise class 1
|
Noise class 1
|
Noise class 1
|
Noise class 1
|
Noise class 1
|
-
|
Noise class 1
|
Noise class 1
|
-
|
Noise class 1
|
-
|
System solutions
|
-
|
-
|
-
|
-
|
-
|
Single Control SSC
|
-
|
SWS Water Management System,
Single Control SSC |
-
|
SWS Water Management System,
Single Control SSC |
SWS Water Management System,
Single Control SSC |
SWS Water Management System,
Single Control SSC |
-
|
SWS Water Management System
|
SWS Water Management System,
Single Control SSC |
-
|
-
|
SWS Water Management System
|
-
|
-
|
SWS Water Management System,
Single Control SSC |
SWS Water Management System,
Single Control SSC |
SWS Water Management System,
Single Control SSC |
SWS Water Management System,
Single Control SSC |
-
|
-
|
-
|
-
|
SWS Water Management System,
Single Control SSC |
SWS Water Management System,
Single Control SSC |
SWS Water Management System
|
-
|
-
|
SWS Water Management System,
Single Control SSC |
SWS Water Management System,
Single Control SSC |
SWS Water Management System,
Single Control SSC |
SWS Water Management System,
Single Control SSC |
-
|
-
|
-
|
SWS Water Management System,
Single Control SSC |
-
|
SWS Water Management System,
Single Control SSC |
SWS Water Management System,
Single Control SSC |
SWS Water Management System,
Single Control SSC |
SWS Water Management System,
Single Control SSC |
SWS Water Management System,
Single Control SSC |
SWS Water Management System,
Single Control SSC |
SWS Water Management System,
Single Control SSC |
SWS Water Management System,
Single Control SSC |
SWS Water Management System,
Single Control SSC |
SWS Water Management System,
Single Control SSC |
SWS Water Management System,
Single Control SSC |
SWS Water Management System,
Single Control SSC |
SWS Water Management System,
Single Control SSC |
SWS Water Management System,
Single Control SSC |
SWS Water Management System,
Single Control SSC |
Pressure
|
-
|
-
|
-
|
-
|
-
|
-
|
High pressure / standard pressure
|
High pressure / standard pressure
|
-
|
-
|
-
|
Low pressure
|
-
|
-
|
High pressure / standard pressure
|
High pressure / standard pressure
|
-
|
-
|
-
|
-
|
High pressure / standard pressure
|
High pressure / standard pressure
|
High pressure / standard pressure
|
High pressure / standard pressure
|
-
|
-
|
High pressure / standard pressure
|
High pressure / standard pressure
|
High pressure / standard pressure
|
High pressure / standard pressure
|
-
|
-
|
-
|
High pressure / standard pressure
|
High pressure / standard pressure
|
High pressure / standard pressure
|
High pressure / standard pressure
|
High pressure / standard pressure
|
-
|
-
|
High pressure / standard pressure
|
-
|
High pressure / standard pressure
|
High pressure / standard pressure
|
High pressure / standard pressure
|
High pressure / standard pressure
|
High pressure / standard pressure
|
High pressure / standard pressure
|
High pressure / standard pressure
|
High pressure / standard pressure
|
High pressure / standard pressure
|
High pressure / standard pressure
|
High pressure / standard pressure
|
High pressure / standard pressure
|
High pressure / standard pressure
|
High pressure / standard pressure
|
High pressure / standard pressure
|
Hygiene
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
Stagnation flush,
Therm. disinfection |
-
|
Stagnation flush,
Therm. disinfection |
-
|
Stagnation flush
|
-
|
-
|
Stagnation flush
|
Stagnation flush
|
-
|
-
|
Therm. disinfection
|
Therm. disinfection
|
-
|
Stagnation flush
|
Stagnation flush,
Therm. disinfection |
Stagnation flush,
Therm. disinfection |
-
|
-
|
-
|
-
|
Stagnation flush,
Therm. disinfection |
Stagnation flush
|
-
|
-
|
-
|
Stagnation flush
|
Stagnation flush
|
Stagnation flush
|
Stagnation flush,
Therm. disinfection |
Therm. disinfection
|
-
|
-
|
Stagnation flush
|
-
|
Stagnation flush
|
Stagnation flush,
Therm. disinfection |
Stagnation flush,
Therm. disinfection |
Stagnation flush
|
Stagnation flush
|
Stagnation flush
|
Stagnation flush
|
Stagnation flush
|
Stagnation flush
|
Stagnation flush,
Therm. disinfection |
Stagnation flush
|
Stagnation flush
|
Stagnation flush,
Therm. disinfection |
Stagnation flush
|
Stagnation flush,
Therm. disinfection |
Energy supply
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
Battery mode
|
-
|
Battery operation,
Mains operation, via SWS or central power pack |
-
|
Battery mode
|
-
|
Mains mode
|
Battery mode
|
Battery mode
|
-
|
via SWS or central power pack
|
-
|
-
|
via SWS or central power pack,
Battery operation, Mains operation |
Battery mode,
Battery operation |
Battery mode,
Battery operation |
Battery mode,
Battery operation |
-
|
-
|
-
|
-
|
via SWS or central power pack
|
Battery mode
|
-
|
-
|
-
|
Battery mode
|
Battery mode
|
Battery mode
|
Battery mode
|
-
|
-
|
-
|
Battery mode
|
-
|
Battery mode
|
Battery mode
|
Battery mode
|
Battery mode
|
Mains mode
|
Mains mode
|
Mains mode
|
Mains mode
|
Mains mode
|
Battery mode
|
Mains mode
|
Mains mode
|
Mains mode
|
Battery operation,
Mains operation, via SWS or central power pack |
Battery mode
|
Certificates
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
SVGW,
WELL |
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
SVGW,
WELL |
-
|
-
|
DVGW
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
SVGW,
WELL |
SVGW,
WELL |
-
|
-
|
WELL
|
-
|
-
|
-
|