Appliance valve COMFORT
|
Combination angle valve COMFORT
|
Double connection angle valve COMFORT
|
Design hand shower bidet
|
F + D ball valve with lever handle
|
Exposed wash basin tap WALIS E
|
Electronic wash basin tap XERIS E
|
WC control EDITION E
|
Electronic wash basin tap PURIS E
|
Self-closing wash basin taps PURIS SC
|
Shower head COMFORT Flex
|
Exposed wash basin tap VITUS VW-C-T
|
Pressure balance valve (PBV)
|
Exposed wash basin tap VITUS VW-AH-T
|
Concealed wash basin tap LINUS W-E-M
|
Angle valve with regulating function COMFORT
|
Electronic wash basin tap PURIS E
|
Compression screw connection - fully assembled
|
Compression screw connection - fully assembled
|
|
Cold water/pre-mixed water
|
HD-M mid - high-pressure mixed water
|
Vandal-resistant design
|
HD-M - high-pressure mixed water
|
HD-K - high-pressure cold water/pre-mixed water
|
Mixed water, ThermoProtect thermostat
|
Mixed water, ThermoProtect thermostat
|
Mixed water
|
HD-M - high-pressure mixed water
|
|||||||||||
Article number
|
|||||||||||||||||||
For a retrofit connection of an appliance to a pre-installed angle valve. With COMFORT handle and grease chamber head part. HD safety combination (EN 1717).
|
With COMFORT handle and grease chamber head part.
|
Angle valve with integrated appliance valve for connecting household appliances. Actuation of angle valve under cover cap.
|
|
Not suitable for drinking water.
|
Infrared sensor-controlled. Battery operation. Suitable for networking with the SCHELL SWS water management system. Configurable via SCHELL Single Control SSC. Connection from rear or, with optional mounting frame, from top, bottom or sides.
|
Infrared sensor-controlled. Excluding power supply. Suitable for networking with the SCHELL SWS water management system. Configurable via SCHELL Single Control SSC. Intended for power supply via SCHELL water management system SWS or central power supply unit.
|
Contact-free infrared sensor flushing facility. For SCHELL COMPACT II concealed WC flush valve. Automatic triggering when leaving the WC (room monitoring). Dual flush. Suitable for networking with the SCHELL SWS water management system. Configurable via SCHELL Single Control SSC. Power supply via SWS, mains adapter or battery compartment.
|
Infrared sensor-controlled. Excluding power supply. Suitable for networking with the SCHELL SWS water management system. Configurable via SCHELL Single Control SSC. Intended for power supply via SCHELL water management system SWS or central power supply unit. With extended outlet 140 mm.
|
Manual actuation with automatic closing. Easy flow time adjustment.
|
Adjustable tilt angle. Vandal-resistant shower head, with soft stream and anti-limescale burls. Angled version minimises likelihood of use for suicide.
|
Triggering via CVD-Touch electronics with automatic closing. Battery operation. With integrated SWS BE-F VITUS wireless bus extender for networking with the SWS water management system.
|
For compensating for the level of pressure in the cold/hot water supply before sampling fittings. Prevents water admixing for fittings with a mixing shaft (e.g. together with small geysers*). Improves adjustment range for single-lever taps. Prevents variations in temperature with pressure fluctuations.
|
Manual open/closed actuation with clinic arm lever.
|
For WBW-E-M concealed masterbox. Infrared sensor-controlled. Excluding power supply. Suitable for networking with the SCHELL SWS water management system. Configurable via SCHELL Single Control SSC. Intended for power supply via SCHELL water management system SWS or central power supply unit.
|
With COMFORT handle. According to DIN 3227.
|
Infrared sensor-controlled. Mains operation (transformer plug). Suitable for networking with the SCHELL SWS water management system. Configurable via SCHELL Single Control SSC. With extended outlet 140 mm.
|
Brass cone compression connection.
|
Brass cone compression connection.
|
|
Scope of delivery
Delivery data
|
Scope of delivery
Delivery data
|
Scope of delivery
Delivery data
|
Scope of delivery
Delivery data
|
Scope of delivery
Delivery data
|
Scope of delivery
Delivery data
|
Scope of delivery
Delivery data
|
Scope of delivery
Delivery data
|
Scope of delivery
Delivery data
|
Scope of delivery
Delivery data
|
Scope of delivery
Delivery data
|
Scope of delivery
Delivery data
|
Scope of delivery
Delivery data
|
Scope of delivery
Delivery data
|
Scope of delivery
Delivery data
|
Scope of delivery
Delivery data
|
Scope of delivery
Delivery data
|
Scope of delivery
Delivery data
|
Scope of delivery
Delivery data
|
|
Technical data
|
Technical data
|
Technical data
|
Technical data
|
Technical data
|
Technical data
|
Technical data
|
Technical data
|
Technical data
|
Technical data
|
Technical data
|
Technical data
|
Technical data
|
Technical data
|
Technical data
|
Technical data
|
Technical data
|
Technical data
|
Technical data
|
|
Filter categories
|
|||||||||||||||||||
Connection
|
3/8"
|
3/8",
ASAG/ASAG easy |
1/2",
ASAG/ASAG easy |
1/2"
|
-
|
1/2"
|
3/8"
|
-
|
3/8"
|
3/8"
|
1/2"
|
1/2"
|
3/8"
|
-
|
-
|
3/8"
|
3/8"
|
-
|
-
|
Outlet
|
3/8",
Hose screw connection, Compression connection |
3/8",
Hose screw connection, Compression connection |
3/8",
Hose screw connection, Compression connection |
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
3/8"
|
-
|
-
|
3/8",
Compression connection |
-
|
-
|
-
|
Equipment
|
Backflow preventer,
Anti-vacuum device |
Backflow preventer
|
Backflow preventer
|
-
|
-
|
-
|
Backflow preventer,
Filter, Flow restrictor |
-
|
Backflow preventer,
Filter |
Filter
|
-
|
Backflow preventer
|
-
|
-
|
-
|
-
|
Backflow preventer,
Filter |
-
|
-
|
Safety class
|
HD
|
EB
|
EB
|
-
|
-
|
-
|
EB
|
-
|
EB
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
EB
|
-
|
-
|
Certificates
|
DVGW,
Belgaqua |
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
WELL,
DVGW, WRAS |
-
|
-
|
-
|
-
|
-
|
DVGW
|
-
|
-
|
-
|
Function
|
-
|
-
|
-
|
Open/closed
|
-
|
Contact-free,
Self-closing electronic |
Contact-free,
Self-closing electronic |
Contact-free,
Self-closing electronic |
Contact-free,
Self-closing electronic |
Self-closing mechanical
|
-
|
Self-closing electronic
|
-
|
Single lever,
Open/closed |
Contact-free,
Self-closing electronic |
-
|
Contact-free,
Self-closing electronic |
-
|
-
|
Temperature
|
-
|
-
|
-
|
Cold water/pre-m. water
|
-
|
Cold water/pre-m. water
|
Mixed water
|
-
|
Mixed water
|
Cold water/pre-m. water
|
-
|
Thermostat (incl. scald protection)
|
Mixed water
|
Thermostat (incl. scald protection),
Mixed water |
Mixed water
|
-
|
Mixed water
|
-
|
-
|
Finish
|
-
|
-
|
-
|
Chrome
|
-
|
Chrome
|
Chrome
|
Stainless steel
|
Chrome
|
Chrome
|
Chrome
|
Chrome
|
White
|
Chrome
|
Chrome
|
Chrome
|
Chrome
|
-
|
-
|
Pressure
|
-
|
-
|
-
|
High pressure / standard pressure,
Low pressure |
-
|
High pressure / standard pressure
|
High pressure / standard pressure
|
High pressure / standard pressure
|
High pressure / standard pressure
|
High pressure / standard pressure
|
-
|
High pressure / standard pressure
|
High pressure / standard pressure
|
-
|
High pressure / standard pressure
|
-
|
High pressure / standard pressure
|
-
|
-
|
System solutions
|
-
|
-
|
-
|
-
|
-
|
SWS Water Management System,
Single Control SSC |
SWS Water Management System,
Single Control SSC |
SWS Water Management System,
Single Control SSC |
SWS Water Management System,
Single Control SSC |
-
|
-
|
SWS Water Management System,
Single Control SSC |
-
|
-
|
SWS Water Management System,
Single Control SSC |
-
|
SWS Water Management System,
Single Control SSC |
-
|
-
|
Hygiene
|
-
|
-
|
-
|
-
|
-
|
Stagnation flush,
Therm. disinfection |
Stagnation flush,
Therm. disinfection |
-
|
Stagnation flush,
Therm. disinfection |
-
|
-
|
Stagnation flush
|
-
|
-
|
Stagnation flush,
Therm. disinfection |
-
|
Stagnation flush
|
-
|
-
|
Energy supply
|
-
|
-
|
-
|
-
|
-
|
Battery mode
|
via SWS or central power pack
|
via SWS or central power pack,
Battery operation, Mains operation |
via SWS or central power pack
|
-
|
-
|
Battery mode
|
-
|
-
|
via SWS or central power pack
|
-
|
Mains mode
|
-
|
-
|
Noises
|
-
|
-
|
-
|
-
|
-
|
-
|
Noise class 1
|
-
|
Noise class 1
|
Noise class 1
|
-
|
-
|
-
|
-
|
-
|
Noise class 1
|
Noise class 1
|
-
|
-
|
Watersaving
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
Dual flush,
Stadium program |
-
|
-
|
-
|
Start/stop function
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|